Once a week (Fume buster)
Wash cashmere bag filters
Visual inspection of the filters
Wash lower module
FOR THE USER
TITLE
PRINTERS
VERSION
REVISED BY
d·gen, Inc. - COMPANY PRIVATE (LEVEL 1)
NOT TO BE DISCLOSED TO UNAUTHORIZED PERSONS – PROHIBIDA SU DIVULGACIÓN A PERSONAS NO AUTORIZADAS
DO NOT REPRODUCE WITHOUT AUTHORIZATION – NO REPRODUCIR SIN AUTORIZACIÓN
MAINTENANCE GUIDE
TELEIOS GRANDE G5
2017DEC04
MUNOZ, ANTONIO
support@dgen.com
Wash the cashmere bag filters with warm water
mixed with nonaggressive detergent. Make sure
its dried before placing the bag to its original
position.
Perform this maintenance procedure wearing
gloves and safety goggles.
Check how clogged the filters are.
Clogged filters may result in:
Poor exhaust of fumes in the fixation unit.
-
Poor fixation process.
-
Suction electric motor failure.
-
Constant tripping of the magnetic contactor.
-
Perform this maintenance procedure wearing
gloves and safety goggles.
Wash the fume buster's lower module with warm
water mixed with nonaggressive detergent. Make
sure its dried before operating again the unit.
Perform this maintenance procedure wearing
gloves and safety goggles.
Perform this maintenance procedure once the
machine is unplugged. Risk of electric shock.