Download Print this page
Transcend CompactFlash 400X Datasheet

Transcend CompactFlash 400X Datasheet

400x compactflash card

Advertisement

Quick Links

T
S
1
6
G
~
6
4
G
C
T
S
1
6
G
~
6
4
G
C
T
S
1
6
G
~
6
4
G
C
Description
Dedicated to fulfill the demanding requirements of
performance-conscious
proudly releases its Extreme 400X CompactFlash
cards. With its amazing performance, the Transcend
400X
CompactFlash
professional photographers and enthusiasts to get the
most from your digital single lens reflex (DSLR)
camera. Users are guaranteed to make consecutive
shooting and non-stop video recording and share their
digital artwork with the world!
Placement
Dimensions
Transcend Information Inc.
F
4
0
0
F
4
0
0
F
4
0
0
photographers,
Transcend
memory
card
allows
Features
• CompactFlash Specification Version 4.1 Compliant
• RoHS compliant products
• Single Power Supply: 3.3V ± 5 % or 5V ± 1 0%
• Operating Temperature: -25
• Storage Temperature: -40
the
• Operating/ Storage Humidity: 5% to 95%
• Operation Modes:
PC Card Memory Mode
PC Card IO Mode
True IDE Mode
• True IDE Mode supports:
Ultra DMA Mode 0 to Ultra DMA Mode 6 (Ultra DMA
mode 5/6 must supply with 3.3V)
MultiWord DMA Mode 0 to MultiWord DMA Mode 4
PIO Mode 0 to PIO Mode 6
• PC Card Mode supports up to Ultra DMA Mode 6
• True IDE mode: Fixed Disk (Default)
• PC Card Mode: Removable Disk (Default)
• Durability of Connector: 10,000 times
• Built-in 15 bit ECC (Error Correction Code) functionality
• Support Global Wear-Leveling to extend product life
• Transfer rate up to read 90MB/s write 60MB/s based on
TestMetrix.
1
400X CompactFlash Card
o
o
C to 85
C
o
o
C to 85
C
V1.0

Advertisement

loading
Need help?

Need help?

Do you have a question about the CompactFlash 400X and is the answer not in the manual?

Questions and answers

Summary of Contents for Transcend CompactFlash 400X

  • Page 1 Users are guaranteed to make consecutive shooting and non-stop video recording and share their digital artwork with the world! Placement Dimensions Transcend Information Inc. Features • CompactFlash Specification Version 4.1 Compliant • RoHS compliant products Transcend • Single Power Supply: 3.3V ± 5 % or 5V ± 1 0% •...
  • Page 2: Specification

    Standby Power Consumption Read (DC 3.3V ℃ Write Transcend Information Inc. No Device Driver Required ATA/ATAPI 7 PIO Mode 0 - 6 Multiword mode 0 - 4 UDMA Mode 0 - 6 Compact Flash Card 16 GB to 64 GB 36.40 ±...
  • Page 3 UDMA6, Windows XP Version 2002 SP2, CrystalDiskMark, copied file 100MB Actual Capacity Model P/N TS16GCF400 TS32GCF400 TS64GCF400 * Note: FAT32 format Transcend Information Inc. Read(MB/s) Write(MB/s) Random Read (MB/s) Random Write (MB/s) 83.67 44.96 86.16 45.82 88.87 39.67 User LBA...
  • Page 4 400X CompactFlash Card Block Diagram Transcend Information Inc. V1.0...
  • Page 5 400X CompactFlash Card Transcend Information Inc. V1.0...
  • Page 6 Ground -CD1 Ground I1Z, OZ3 D121 I1Z, OZ3 I1Z, OZ3 I1Z, OZ3 I1Z, OZ3 -CE2 -VS1 Ground Transcend Information Inc. PC Card I/O Mode Signal In, Out Pin Num Name Type Type Ground I1Z, OZ3 I1Z, OZ3 I1Z, OZ3 I1Z, OZ3...
  • Page 7 11) Signal usage in PC Card I/O and Memory Mode when Ultra DMA mode protocol DMA Read is active. 12) Signal usage in PC Card I/O and Memory Mode when Ultra DMA protocol is active. Transcend Information Inc. PC Card I/O Mode...
  • Page 8: Input Leakage Current

    Note: In Table 3 below, x refers to the characteristics described in Table 4. For example, OT3 refers to Totem pole output with a type 3 output drive characteristic. Type Totempole Tri-State N-P Channel P-Channel Only N-Channel Only Transcend Information Inc. Table 1: Input Leakage Current Symbol Conditions Vih = Vcc / Vil = Gnd RPU1 Vcc = 5.0V RPD1 Vcc = 5.0V...
  • Page 9: Output Drive Characteristics

    Output Drive Characteristics Type Parameter Output Voltage Output Voltage Output Voltage Tri-State Leakage Current Transcend Information Inc. Table 4: Output Drive Characteristics Symbol Conditions Ioh = -4 mA Iol = 4 mA Ioh = -4 mA Iol = 4 mA...
  • Page 10: Signal Description

    -CD1, -CD2 (PC Card I/O Mode) -CD1, -CD2 (True IDE Mode) Transcend Information Inc. 8,10,11,12, These address lines along with the -REG signal are used to select the following: 14,15,16,17, The I/O port address registers within the CompactFlash Storage Card , the...
  • Page 11 (PC Card Memory Mode) (PC Card I/O Mode) (True IDE Mode) Transcend Information Inc. These input signals are used both to select the card and to indicate to the card 7,32 whether a byte or a word operation is being performed. -CE2 always accesses the odd byte of the word.-CE1 accesses the even byte or the Odd byte of the...
  • Page 12 HSTROBE (All Modes - Ultra DMA Protocol DMA Write) Transcend Information Inc. This signal is not used in this mode. The Input Acknowledge signal is asserted by the CompactFlash Storage Card when the card is selected and responding to an I/O read cycle at the address that is on the address bus.
  • Page 13 (PC Card I/O Mode) INTRQ (True IDE Mode) Transcend Information Inc. This signal is not used in this mode. The I/O Write strobe pulse is used to clock I/O data on the Card Data bus into the CompactFlash Storage Card controller registers when the CompactFlash Storage Card is configured to use the I/O interface.
  • Page 14 (True IDE Mode) (PC Card Memory Mode) (PC Card I/O Mode) (True IDE Mode) Transcend Information Inc. This signal is used during Memory Cycles to distinguish between Common Memory and Register (Attribute) Memory accesses. High for Common Memory, Low for Attribute Memory.
  • Page 15 (PC Card I/O Mode) -IOCS16 (True IDE Mode) Transcend Information Inc. Voltage Sense Signals. -VS1 is grounded on the Card and sensed by the Host so that the CompactFlash Storage Card CIS can be read at 3.3 volts and -VS2 is reserved by PCMCIA for a secondary voltage and is not connected on the Card.
  • Page 16: Absolute Maximum Conditions

    Pull up resistance Pull down resistance 1. Include CE1, CE2, HREG, HOE, HIOE, HWE, HIOW pins 2. Include CE1, CE2, HREG, HOE, HIOE, HWE, HIOW, CSEL (P35), PDIAG, DASP pins Transcend Information Inc. Symbol Min. ─ ─ ─ ─ 2.92 Symbol Min.
  • Page 17 3) Voltage output high and low values shall be met at the source connector to include the effect of series termination. 4) A device shall have less than 64 μ state. Transcend Information Inc. Table: Input Characteristics (UDMA Mode > 4) ) - (V- current value...
  • Page 18: Signal Interface

    AC timing requirements: (the number of sockets wired in parallel) multiplied by (50 pF with DC current 700 2) Resistor is optional. 3) Status Signals: the socket shall present a load to the card no larger than 50 pF Transcend Information Inc. Card Pull-up to V 500 K 50 K Ω...
  • Page 19 4) The -WAIT and IORDY signals shall be ignored by the host. Devices supporting CF Advanced timing modes shall also support slower timing modes, to ensure operability with systems that do not support CF Advanced timing modes Transcend Information Inc. 400X CompactFlash Card A low state and 100 μ...
  • Page 20: Compactflash Card

    Ultra DMA mode. Shows signals also requiring a pull-up or pull-down resistor at the host. The actual termination values should be selected to compensate for transceiver and trace impedance to match the characteristic cable impedance. Transcend Information Inc. Table: Typical Series Termination for Ultra DMA Host Termination...
  • Page 21 For True IDE mode operation using a cable with IDE (ATA) type 40 pin connectors it is recommended that the host sense the cable type using the method described in the ANSI INCITS 361-2002 AT Attachment - 6 standard, to prevent use of Ultra DMA with a 40 conductor cable. Transcend Information Inc. 400X CompactFlash Card V1.0...
  • Page 22: Attribute Memory Read Timing Specification

    Note: All times are in nanoseconds. Dout signifies data provided by the CompactFlash Storage Card to the system. The -CE signal or both the -OE signal and the -WE signal shall be de-asserted between consecutive cycle operations. Transcend Information Inc. Symbol...
  • Page 23 Address Setup Time Write Recovery Time Data Setup Time for WE Data Hold Time Note: All times are in nanoseconds. Din signifies data provided by the system to the CompactFlash Storage Card . Transcend Information Inc. Item Symbol tc(W) tw(HWE)
  • Page 24: Common Memory Read Timing Specification

    -OE cycle to cycle time is greater than the Wait Width time. The Max Wait Width time can be determined from the Card Information Structure. The Wait Width time meets the PCMCIA PC Card specification of 12µs but is intentionally less in this specification. Transcend Information Inc. Cycle Time Mode: IEEE...
  • Page 25: Common Memory Write Timing Specification

    -HWE cycle to cycle time is greater than the Wait Width time. The Max Wait Width time can be determined from the Card Information Structure. The Wait Width time meets the PCMCIA PC Card specification of 12µs but is intentionally less in this specification. Transcend Information Inc. Cycle Time Mode: IEEE...
  • Page 26: I/O Input (Read) Timing Specification

    CEx Setup before HIOE CEx Hold following HIOE HREG Setup before HIOE HREG Hold following HIOE Wait Delay Falling from HIOE Data Delay from Wait Rising Wait Width Time Transcend Information Inc. Cycle Time Mode: 250 ns IEEE Symbol Symbol td(HIOE)
  • Page 27: I/O Output (Write) Timing Specification

    CEx Setup before HIOW CEx Hold following HIOW HREG Setup before HIOW HREG Hold following HIOW Wait Delay Falling from HIOW HIOW high from Wait high Wait Width Time Transcend Information Inc. Cycle Time Mode: IEEE Symbol Symbol tsu(HIOW) tDVIWH...
  • Page 28 IORDY negated at the time tA after the activation of -HIOE or -HIOW, then tRD shall be met and t5 is not applicable. 4) t7 and t8 apply only to modes 0, 1 and 2. For other modes, this signal is not valid. 5) IORDY is not supported in this mode. Transcend Information Inc. Item 1250...
  • Page 29 400X CompactFlash Card Transcend Information Inc. V1.0...
  • Page 30 -HIOE negated width (min) -HIOW negated width (min) -HIOE to DMARQ delay (max) -HIOW to DMARQ delay (max) CEx valid to –HIOE / -HIOW CEx hold Transcend Information Inc. 400X CompactFlash Card Mode 0 Mode 1 Mode 2 Mode 3...
  • Page 31 400X CompactFlash Card True IDE Ultra DMA Mode Read/Write Timing Specification Ultra DMA operations can take place in any of the three basic interface modes: PC Card Memory mode, PC Card I/O mode, Transcend Information Inc. V1.0...
  • Page 32 Only one Ultra DMA mode shall be selected at any given time. All timing requirements for a selected Ultra DMA mode shall be satisfied. Devices supporting any Ultra DMA mode shall also support all slower Ultra DMA modes. Transcend Information Inc. Pin # (Non PC CARD MEM...
  • Page 33 NOTE -If a data transfer is terminated before completion, the assertion of INTRQ should be passed through to the host software driver regardless of whether all data requested by the command has been transferred. Transcend Information Inc. V1.0...
  • Page 34 For example, in the case of tRFS, both STROBE and –DMARDY transitions are measured at the sender connector. 3) The parameter tCYC shall be measured at the recipient’s connector farthest from the sender. Transcend Information Inc. UDMA UDMA UDMA...
  • Page 35 Minimum time before driving IORDY ZIORDY Setup and hold times for -DMACK (before assertion or negation) Time from STROBE edge to negation of DMARQ or assertion of STOP (when sender terminates a burst) Transcend Information Inc. 400X CompactFlash Card Notes 2, 5 2, 5 4, 6 V1.0...
  • Page 36 3)The parameters tDVSIC and tDVHIC shall be met for lumped capacitive loads of 15 and 40 pF at the IC where all signals have the same capacitive load value. Noise that may couple onto the output signals from external sources has not been included in these values. Transcend Information Inc. UDMA UDMA...
  • Page 37 120 nsec apart. The settled VOH level shall be measured as the average output high level under the defined testing conditions from 100 nsec after 80% of a rising edge until 20% of the subsequent falling edge. Transcend Information Inc. 400X CompactFlash Card [V/ns]...
  • Page 38: Card Configuration

    I/O cards. Multiple Function CompactFlash Storage Cards Table: CompactFlash Storage Card Registers and Memory Space Decoding -CE2 -CE1 -REG Transcend Information Inc. A8-A4 400X CompactFlash Card SELECTED SPACE Standby and UDMA transfer Configuration Registers Read...
  • Page 39 Table: PC Card Memory Mode UDMA Function -DMARQ -DMACK -CE2 -CE1 -INPACK -REG Table: CompactFlash Storage Card Configuration Registers Decoding -CE2 -CE1 -REG Transcend Information Inc. -DMARDY STROBE STOP -HIOE -WAIT -HIO (R)-WAIT (R)-HIOE / or \ 0 or 1...
  • Page 40: Attribute Memory Function

    Notes: 1) In UDMA operation, the -REG (-DMACK) signal shall be asserted only in response to -DMARQ. 2) The -CE signals or both the -OE signal and the -WE signal shall be de-asserted between consecutive cycle operations. Transcend Information Inc. Table: Attribute Memory Function...
  • Page 41 400X CompactFlash Card Configuration Option Register (Base + 00h in Attribute Memory) Transcend Information Inc. V1.0...
  • Page 42 400X CompactFlash Card Card Configuration and Status Register (Base + 02h in Attribute Memory) Transcend Information Inc. V1.0...
  • Page 43 400X CompactFlash Card Pin Replacement Register (Base + 04h in Attribute Memory) Transcend Information Inc. V1.0...
  • Page 44 400X CompactFlash Card Socket and Copy Register (Base + 06h in Attribute Memory) Transcend Information Inc. V1.0...
  • Page 45: I/O Transfer Function

    Word Input Access (16 bits) Word Output Access (16 bits) I/O Read Inhibit I/O Write Inhibit High Byte Input Only (8 bits) High Byte Output Only (8 bits) Transcend Information Inc. Table: PCMCIA Mode I/O Function -REG -CE2 -CE1 Write...
  • Page 46 -DMARQ DMACK -CE2 -CE1 -INPACK -REG Transcend Information Inc. Table: PC Card I/O Mode UDMA Function -DMARDY STROBE STOP -HIOE -WAIT -HIOW (R)-WAIT (R)-HIOE / or \ 0 or 1 0 or 1 0 or 1 0 or 1 0 or 1...
  • Page 47: Common Memory Transfer Function

    Byte Write (8 bits) Word Read (16 bits) Word Write (16 bits) Odd Byte Read Only (8 bits) Odd Byte Write Only (8 bits) Ultra DMA Write Ultra DMA Read Transcend Information Inc. -REG -CE2 -CE1 None Don’t Care Don’t Care Don’t...
  • Page 48: True Ide Mode I/O Transfer Function

    3. The card is permitted to monitor the –OE (-ATA SEL) signal at any time(s) and switch to True IDE mode upon detection of a continuous low level on pin for an extended period of time. Table: True IDE Mode I/O Function defines the function of the operations for the True IDE Mode. Transcend Information Inc. 400X CompactFlash Card V1.0...
  • Page 49 Note: The value “1” defined for D3 of the N+0 words indicates that no write-protect switch controls writing the ATA registers. The value “0” defined for D7 in the N+2 words indicates that there is not more than a single speed extension byte. Transcend Information Inc. 400X CompactFlash Card V1.0...
  • Page 50 The PCMCIA interface connects peripherals to the host using four register mapping methods. Table 39 is a detailed description of these methods: Transcend Information Inc. 400X CompactFlash Card V1.0...
  • Page 51 400X CompactFlash Card I/O Primary and Secondary Address Configurations Table: Primary and Secondary I/O Decoding Transcend Information Inc. V1.0...
  • Page 52: Contiguous I/O Mapped Addressing

    When the system decodes a contiguous block of I/O registers to select the CompactFlash Storage Card, the registers are accessed in the block of I/O space decoded by the system as follows: Table: Contiguous I/O Decoding Transcend Information Inc. V1.0...
  • Page 53: Memory Mapped Addressing

    When the CompactFlash Storage Card registers are accessed via memory references, the registers appear in the common memory space window: 0-2K bytes as follows: True IDE Mode Addressing When the CompactFlash Storage Card is configured in the True IDE Mode, the I/O decoding is as follows: Transcend Information Inc. 400X CompactFlash Card V1.0...
  • Page 54 (Not Ready, Write Fault, etc.) or when an invalid command has been issued. Bit 1 This bit is 0. Bit 0 (AMNF) This bit is set in case of a general error. Transcend Information Inc. 400X CompactFlash Card V1.0...
  • Page 55 (Drive #) of the PCMCIA Socket & Copy configuration register. Bit 3 (HS3): when operating in the Cylinder, Head, Sector mode, this is bit 3 of the head number. It is Bit 27 in the Logical Block Address mode. Transcend Information Inc. 400X CompactFlash Card V1.0...
  • Page 56 It is recommended that media access commands (such as Read Sectors and Write Sectors) that end with an error condition should have the address of the first sector in error in the command block registers. Transcend Information Inc. 400X CompactFlash Card V1.0...
  • Page 57 CompactFlash Storage Card are disabled. This bit also controls the Int bit in the Configuration and Status Register. This bit is set to 0 at power on and Reset. Bit 0: this bit is ignored by the CompactFlash Storage Card. Transcend Information Inc. 400X CompactFlash Card V1.0...
  • Page 58 Bit 2 (-HS0): this bit is the negation of bit 0 in the Drive/Head register. Bit 1 (-nDS1): this bit is 0 when drive 1 is active and selected. Bit 0 (-nDS0): this bit is 0 when the drive 0 is active and selected. Transcend Information Inc. 400X CompactFlash Card V1.0...
  • Page 59 Read Long Sector Read Multiple Read Sector(s) Read Verify Sector(s) Recalibrate Request Sense Seek Set Feature Set Multiple Mode Set Sleep Mode Standby Standby Immediate Transcend Information Inc. Code E5 or 98h – – – – – – – – –...
  • Page 60 CY = Cylinder Low/High register DH = Head No. (0 to 15) of Drive/Head register LBA = Logic Block Address Mode Support – = Not used for the command Y = Used for the command Transcend Information Inc. – – – –...
  • Page 61: Check Power Mode - 98H Or E5H

    Cyl Low (4) Sec Num (3) Sec Cnt (2) Feature (1) Diagnostic Codes are returned in the Error Register at the end of the command. Code Transcend Information Inc. 98h or E5h Drive Drive Error Type No Error Detected Formatter Device Error...
  • Page 62: Erase Sector(S) - C0H

    Bit -> Command (7) C/D/H (6) Cyl High (5) Cyl Low (4) Sec Num (3) Sec Cnt (2) Feature (1) Transcend Information Inc. Drive Cylinder High (LBA 23-16) Cylinder Low (LBA 15-8) Sector Number (LBA 7-0) Sector Count Drive Drive...
  • Page 63: Identify Device (Ech)

    23-26 XXXXh 27-46 XXXXh 8001h 0000h 0200h 0000h Transcend Information Inc. Drive Total Data Field Type Information General configuration - signature for the CompactFlash Storage Card General configuration – Bit Significant with ATA-4 definitions. Default number of cylinders Reserved Default number of heads...
  • Page 64 XXXXh XXXXh 93-127 0000h XXXXh 129-159 0000h 81F4h 0000h Transcend Information Inc. Total Data Field Type Information PIO data transfer cycle timing mode Obsolete Field Validity Current numbers of cylinders Current numbers of heads Current sectors per track Current capacity in sectors (LBAs)(Word 57 = LSW, Word 58 = MSW)
  • Page 65 Word 1: Default Number of Cylinders This field contains the number of translated cylinders in the default translation mode. This value will be the Transcend Information Inc. Key management schemes supported CF Advanced True IDE Timing Mode Capability and Setting...
  • Page 66 1 of word 53 to one and support the fields contained in words 64 through 70. Current Number of Cylinders, Heads, Sectors/Track These fields contains the current number of user addressable Cylinders, Heads, and Sectors/Track in the Transcend Information Inc. 400X CompactFlash Card V1.0...
  • Page 67 Card shall return a value of zero in this field. Recommended Multiword DMA transfer cycle time Word 66 of the parameter information of the Identify Device command is defined as the recommended Transcend Information Inc. 400X CompactFlash Card V1.0...
  • Page 68 Bit 0 of word 83 shall be set to zero; the CompactFlash Storage Card does not support the Download Microcode command. Bit 1 of word 83 shall be set to zero; the CompactFlash Storage Card does not support the Read DMA Queued Transcend Information Inc. 400X CompactFlash Card V1.0...
  • Page 69 Bit 11: 1 = Ultra DMA mode 3 is selected, 0 = Ultra DMA mode 3 is not selected Bit 10: 1 = Ultra DMA mode 2 is selected, 0 = Ultra DMA mode 2 is not selected Transcend Information Inc. 400X CompactFlash Card...
  • Page 70 If set to 0, indicates that CompactFlash Storage Card does not support security mode feature set. Word 160: Power Requirement Description This word is required for CompactFlash Storage Cards that support power mode 1. Bit 15: VLD Transcend Information Inc. 400X CompactFlash Card V1.0...
  • Page 71 Value Bits 8-6: Advanced True IDE PIO Mode Selected Indicates the current True IDE PIO mode selected on the card. Value Transcend Information Inc. Maximum PIO mode timing selected Specified in word 64 PIO Mode 5 PIO Mode 6...
  • Page 72 Indicates the Maximum Memory timing mode supported by the card. Value Bits 8-6: Maximum PC Card I/O UDMA timing mode supported Indicates the Maximum PC Card I/O UDMA timing Transcend Information Inc. Specified in word 64 PIO Mode 5 PIO Mode 6...
  • Page 73 This bit, when set, indicates that the PC Card UDMA support values in bits 11-6 are valid. When this bit is cleared, PC Card Memory and IO Modes are not supported by the device Transcend Information Inc. Maximum PC Card I/O UDMA timing mode Supported...
  • Page 74: Idle Immediate - 95H Or E1H

    Command (7) C/D/H (6) Cyl High (5) Cyl Low (4) Sec Num (3) Sec Cnt (2) Feature (1) NOP - 00h Transcend Information Inc. 97h or E3h Drive Timer Count (5 msec increments) 95h or E1h Drive Drive Number of Sectors 400X CompactFlash Card Max Head (no.
  • Page 75: Read Buffer - E4H

    Bit -> Command (7) C/D/H (6) Cyl High (5) Cyl Low (4) Sec Num (3) Sec Cnt (2) Feature (1) Read DMA – C8h Read Long Sector - 22h or 23h Transcend Information Inc. Drive Drive 400X CompactFlash Card V1.0...
  • Page 76 400X CompactFlash Card Read Multiple - C4h Read Sector(s) - 20h or 21h Read Verify Sector(s) - 40h or 41h Recalibrate - 1Xh Transcend Information Inc. V1.0...
  • Page 77: Set Features (Efh)

    400X CompactFlash Card Request Sense - 03h The extended error code is returned to the host in the Error Register. Seek - 7Xh Set Features – EFh Transcend Information Inc. V1.0...
  • Page 78 When the subcommand disable write cache is issued, the CompactFlash Storage Card shall initiate the sequence to flush cache to non-volatile memory before command completion. Feature 03h allows the host to select the PIO or Multiword DMA transfer mode by specifying a value in the Sector Transcend Information Inc. V1.0...
  • Page 79: Set Multiple Mode - C6H

    For Cards which support DMA, one Multiword DMA mode shall be selected at all times. The host may change the selected modes by the Set Features command. Set Multiple Mode - C6h Set Sleep Mode- 99h or E6h Standby - 96h or E2h Transcend Information Inc. 400X CompactFlash Card V1.0...
  • Page 80 400X CompactFlash Card Standby Immediate - 94h or E0h Translate Sector - 87h Translate Sector Information Transcend Information Inc. V1.0...
  • Page 81: Write Dma - Cah

    400X CompactFlash Card Wear Level - F5h Write Buffer - E8h Write DMA – CAh Transcend Information Inc. V1.0...
  • Page 82 400X CompactFlash Card Write Long Sector - 32h or 33h Write Multiple Command - C5h Write Multiple without Erase – CDh Transcend Information Inc. V1.0...
  • Page 83 400X CompactFlash Card Write Sector(s) - 30h or 31h Write Sector(s) without Erase - 38h Write Verify - 3Ch Transcend Information Inc. V1.0...
  • Page 84: Error Posting

    Read Verify Sectors Recalibrate Request Sense Security Disable Password Security Erase Prepare Security Erase Unit Security Freeze Lock Security Set Password Security Unlock Seek Set Features Transcend Information Inc. Error Register IDNF ABRT AMNF 400X CompactFlash Card Status Register DRDY CORR V1.0...
  • Page 85 Write Multiple w/o Erase Write Sector(s) Write Sector(s) w/o Erase Write Verify Invalid Command Code Error and Status Register summarizes the valid status and error value for all the CF-ATA Command set. Transcend Information Inc. Error Register IDNF ABRT AMNF 400X CompactFlash Card...
  • Page 86: Smart Command Set

    SMART Data Structure BYTE F / V 2-114 115-116 117-361 364-365 368-369 Transcend Information Inc. SMART Feature Register Values Revision code Vendor specific Power cycle count of the device Vendor specific Off line data collection status Self-test execution status byte...
  • Page 87 X=the content of the byte is vendor specific and may be fixed or variable. R=the content of the byte is reserved and shall be zero. N=Nth Management Unit. * 4 Byte value : [MSB] [2] [1] [LSB] Transcend Information Inc. Conveyance self-test routine recommended polling time (in minutes) Reserved Firmware Version/Date Code...
  • Page 88 Transcend makes no warranty, either expressed or implied, as to its accuracy and assumes no liability in connection with the use of this product. Transcend reserves the right to make changes to the specifications at any time without prior notice. TAIWAN Los Angeles: Maryland: Transcend Information Inc. TS XG CF400 XX JAPAN CHINA GERMANY HONG KONG...

This manual is also suitable for:

Compactflash ts16g-64gcf400Ts16gcf400Ts64gcf400