Download Print this page

Troubleshooting; Technical Specifications; General Safety Rules; Warranty - Waterco HYDROCHLOR TS 20 SC Owner's Manual

Advertisement

TROUBLESHOOTING

SYMPTOM
POSSIBLE CAUSE
Low chlorine level in pool
Operating time too short
Production control set too
Pool chemistry not correct
Unit does not operate
No electrical power
Hydrochlor TS® switch off
Not keeping time
Time clock setting,
power outage and power
Electrical fault

TECHNICAL SPECIFICATIONS

Output
Input Watt
Model
current DC
(kW) max
(A) max
20 SC
290
20
25 SC
330
25
30 SC
380
30
Model
Primary Input )Volts)/ Frequency
(Hz)
Input Power (W)
Maximum Total Current (A)
Cell Voltage (V)
Degree of Protection
* Protection to weather is required for installation outdoor.
Indoor use only.
Cell Housing dimensions
A (mm)
423.5
REMEDY
Increase operating time
Set production higher
low
Low salt
Add required amount of salt
Have water tested
Connect power, check fuse,
switch on Hydrochlor TS
Make sure battery have been
charged for a least 70hr to
drained
achieve max capacity
Return to distributor for
repair
Max Pool Capacity (L)
Chlorine
Climate
Production
(g/hr)
Temperate
Tropical
20
80,000
48,000
25
100,000
60,000
30
120,000
72,000
20 SC
25 SC
30 SC
220-240/50-
220-240/50-
220-240/50-
60
60
60
290
330
380
10
10
10
6 - 8
6 - 8
6 - 8
IP23
IP23
IP23
B (mm)
C (mm)
D (mm)
136.5
280.0
188.8

GENERAL SAFETY RULES

1)
The equipment mentioned in this manual is specially designed for the sanitizing of
water in swimming pools.
2) It is designed to work with clean water at a temperature not exceeding 35°C (95°F).
3) The installation should be carried out in accordance to the safety instructions of
swimming pools especially Standard HD 384.7.702 and the specific instructions for
each facility.
4) The rules enforced on accident prevention should be carefully followed.
5) Any modification of the chlorinator requires the prior consent of the manufacturer.
®
Original replacement parts and accessories authorized by the manufacturer ensure a
high level of safety. The manufacturer accepts no liability for the damage and injuries
caused by unauthorized replacement parts and accessories.
6) During operation, some parts of the chlorinator are subject to dangerous electric
voltage. Work may only be performed on the chlorinator or on the equipment
connected to it after disconnecting them and the starting device from the mains power.
7) The user should make sure that assembly and maintenance tasks are carried out
by qualified authorized persons and that these persons have first carefully read the
Service and Installation Instructions.
8) The operating safety of the chlorinator is only guaranteed if the Installation and Service
instructions are correctly followed.
9) The limit values stated in the Technical Specifications should not be exceeded under
any circumstance.
10) In the event of defective operation or fault, contact the manufacturer's Technical
Support Department or its nearest Authorized Agent.
11) If the supply cord is damaged, it must be replaced by the manufacturer or its service
agent or a similarly qualified person.
12) This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
13) The appliance is not intended for use by young children. Young children should be
supervised to ensure that they do not play with the appliance.
These chlorinators are approved and conformed to AS3136 Swimming Pool Equipment, as
a prescribed article under Australian Registration.
These chlorinators conform to the Australian Electromagnetic Compatibility Standard
marked by the C-tick.

WARRANTY

Two Years Warranty:
Hydrochlor TS
Titanium cell
Power pack
Commercial Installations
*Please refer to Waterco's Warranty terms and conditions
®
Chlorinator
Waterco Hydrochlor TS
®
I pg 09
2 years*
2 years
2 years
1 year

Advertisement

loading

This manual is also suitable for:

Hydrochlor ts 25 scHydrochlor ts 30 sc