Installing the Power Pack
Choose a location for the Hydrochlor TS
Housing and filtration pump so that both may be connected/disconnected easily.
The Hydrochlor TS
Power Pack should not be mounted in areas where chemicals
®
are stored (e.g. acid and chlorine). Also ensure that the Hydrochlor TS
can be connected to the mains power outlet of the pool area. Note that this outlet
must meet the current applicable local standards at the time of installation.
The PUMP socket outlet in the base of the Hydrochlor TS
to the filtration pump only. Do not use a double adaptor to connect another pump
as this will overload the system and void warranty.
NOTE: For installations running on off-peak electricity supply, like Queensland Tariff
33, it is required to connect the Power pack to power supply for a period of at least
24 hours to fully charge the back-up battery of the timer.
Installing/Connecting the Hydrochlor TS
The Cell/Housing assembly should be plumbed into the
pool return line after all other accessories (and prior to any
heating take-offs). Note any water flow direction on the Cell/
Housing. The Cell will need to be removed from the Housing
periodically for cleaning – do not place it where its removal
can be difficult/obstructed.
The Cell Cable is connected to the Cell Connector under the
Hydrochlor TS
®
Power Pack cover.
Ensure that the 3 connections (2 for Cell Power and 1 for Gas
Sensing) are not loose. A loose connection is likely to cause
arcing which may damage the entire system.
NOTE: Connect all plumbing to the Hydrochlor taking care that all joints are glued
or tightened securely to prevent leaking.
Allow 24 hours for glue (solvent) to set before starting the Hydrochlor TS
Power Pack close enough to the Cell/
®
®
Power Pack
's Power Pack is dedicated
®
Self Cleaning Cell
®
®
.
TIME SWITCH OPERATION
Setting the time
To set current time, rotate minute hand until arrow-head aligns with correct time.
The clock operates in a 24 hour time sequence
Setting Filtration and Chlorinator Operation Time.
To set ON/OFF times, move all tappets between ON and OFF times required to
outer position.
I.E. to set ON at 7.30 a.m. and OFF at 10.30 a.m. move all tappets between 7.30 and
10.30 to outer position (see fig. 1).
Tappets in OFF position
Manual Override switch (see fig. 2)
ON Position:
the time switch is permanently ON irrespective of tappet positions. This is the
recommended setting to work in combination with Waterco's Aquamaster or
ChemfloPlus.
AUTO Position:
the time switch is operating on timed control as determined by tappet positions.
This the automatic operation position.
OFF Position:
the time switch is permanently OFF irrespective of tappet positions.
Waterco Hydrochlor TS
Tappets in ON position
Figure 1
®