Table GD-2— General Data
C o o ling P e rf o rm anc e
1
Gro ss Coo ling Capacity, btu (kW)
M atched Air Handler
Condensing Unit Only
2
A RI Net Cooling Capacity
3
System P ower kW
Condensing Unit P ower kW
C o m press o r
Number
Type
No. M o tors (each)
M oto r HP (kW)
M oto r RP M
4
A R I S o und R at ing (B els)
S yst em D at a
5
No. Refrigerant Circuits
Suctio n Line in. (mm) OD
Liquid Line in. (mm) OD
O utdo o r C o il — T ype
Tube Size in. (mm) OD
Face A rea, sq. ft (m2)
Rows
Fins P er Inch
O utdo o r F an T ype
No. Used
Diameter in. (mm)
Drive Type
No. Speeds
CFM 6 (m3/h)
No. M o tors
M oto r HP (kW)
M oto r RP M
R - 22 R ef rigerant C harge , lb
Notes:
1. Cooling Performance is rated at 95°F (35°C) ambient, 80°F (26.7°C) entering dry bulb, 67°F (19.4°C) entering wet bulb and nominal cfm listed. ARI rating cfm is 350 cfm/ton for this
product. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of
nominal cfm. Certified in accordance with the Unitary Large Equipment certification program, which is based on ARI Standard 340/360 or 365-00.
2. Condensing Unit Only Gross Cooling Capacity rated at 45°F (7.2°C) saturated suction temperature and at 95°F (35°C) ambient.
3. ARI Net Cooling Capacity is calculated with matched blower coil and 25 ft (7.2 m) of 1.375, 0.500 OD interconnecting tubing (1 5/8" suction and 5/8" liquid for TTA200F). EER and/or
SEER are rated at ARI conditions and in accordance with DOE test procedures. Integrated Part Load Value is based on ARI Standard 340/360 or 365-00. Units are rated at 80°F (26.7°C)
ambient, 80°F (26.7°C) entering dry bulb, and 67°F (19.4°C) entering wet bulb at ARI rated cfm.
4. Sound Rating shown is tested in accordance with ARI Standard 270.
5. System Data based on maximum linear length 80 ft (26.7 m) Maximum lift: suction 60 ft (18.3 m) liquid 60 ft (18.3 m) For greater lengths, refer to refrigerant piping applications
manual.
6. Outdoor Fan cfm is rated with standard air-dry coil outdoor.
7. Refrigerant (operating) charge is for condensing unit (all circuits) with matching blower coils and 25 ft (7.6 m) of interconnecting refrigerant lines.
12
General
Data
TTA 1 00C
TTA 1 25B
1 1 3,000(33.09)
1 34,000(39.24)
1 1 3,000(33.09)
1 30,000(38.06)
11 0,000(32.21)
1 30,000(38.06)
1 0.34
9.31
2
Copeland Scro ll Climatuff™Scrol
1
4.1 6(3.1 0)
5.20(3.9)
2875
8.8
1
1 .375(34.9)
1 .1 25(28.58)
0.500(1 2.7)
0.375(9.53)
P late Fin
Plate Fin
0.375(9.5)
0.375(9.5)
24.0(2.23)
24.0(2.23)
2
20
Propeller
P ropeller
1
28.00(71 1 .2)
28.00(711 .2)
Direct
Direct
1
8120(1 3795.0)
81 20(1 3795.0)
1
0.75(.56)
0.75(.56)
925
7
( kg)
20.5(9.30)
23.6(1 0.70)
TTA 1 55B
1 66,000(48.60)
1 67,000(48.90)
1 66,000(48.60)
1 67,000(48.90)
1 60,000(46.85)
1 61 ,000(47.1 4)
1 2.63
1 6.1 8
1 1 .52
1 4.33
2
2
Scroll
1
1
6.25(4.7)
2875
2875
8.8
8.8
2
2
1 .375(34.9)
0.500(1 2.7)
P late Fin
0.375(9.5)
33.33(3.1 0)
2
2
20
20
Propeller
1
2
26.00(660.4)
Direct
1
1
9400(15970.60)
9400(1 5970.60)
1
1
0.33(.25)
925
925
30.0(1 3.61 )
Condensing Unit
TTA 1 55C
TTA 200B
220,000(64.42)
220,000(64.42)
21 2,000(62.07)
1 6.1 7
21 .22
1 4.28
1 8.56
2
2
Scro ll
Scroll
1
1
6.25(4.7)
8.33(6.21)
2875
2875
8.8
8.8
1
2
1 .625(41 .3)
1 .375(34.9)
0.625(1 5.9)
0.500(1 2.7)
Plate Fin
P late Fin
0.375(9.5)
0.375(9.5)
33.33(3.1 0)
50.2(4.66)
2
2
20
1 8
P ro peller
P ropeller
2
2
26.00(660.4)
28.00(71 1 .2)
Direct
Direct
1
1
1 3400(22766.60)
1
2
0.33(.25)
0.75(.56)
925
925
28.0(12.70)
39.5(1 7.92)
TTA200F
220,000(64.42)
220,000(64.42)
21 2,000(62.07)
20.72
1 6.81
2
Copeland Scroll
1
8.29(6.1 8)
2900
9.2
1
1 .625(41 .3)
0.625(15.9)
Plate Fin
0.375(9.5)
52.9(4.91 )
2
1 8
P ro peller
2
28.00(71 1 .2)
Direct
1
1 21 00(20558)
2
0.75(.56)
925
41 .3(1 8.7)-R41 0A