Section 6 - Storage

Drain System Identification

Air-Actuated Single-Point Drain System

a
c c
a

Manual Drain System

a
a
Air‑Actuated Single‑Point Drain System

Boat in the Water

NOTE: This procedure is written for the air pump that was shipped with the engine from the factory. However, any air source
can be used.
1.
Close the seacock (if equipped) or remove and plug the water inlet hose.
2.
Obtain the air pump.
3.
Remove the threaded cap from the air connection.
4.
Ensure that the lever on top of the air pump is against the handle (horizontal).