TIME ZONE
To automtically set the time display to your time-zone, change the time zone in SETUP page of
previous section from '0:00' (default) to your time zone (e.g.+1:00 for Germany).
TIME SERVER CONNECTION STATUS
After the console has connected to the internet, it will
attempt to connect to the internet time server to obtain
the UTC time. Once the connection succeeds and the
console's time has been updated, the "
appear on the LCD.
The time will automatically synchronize Internet time server at 12:00AM and 12:00PM per day.
Also you can press the [REFRESH ] key to get the internet time manually within 1 minute.
ADVANCE SETTING IN WEB INTERFACE
Press "ADVANCED" key at the top of web interface to enter the advance setting page, this
page allow you to set and view the calibration data of the console, as well as update the
firmware version on PC web browser.
Press "SETUP" icon to
Setup page
Select setting unit
Outdoor and Ch 1~7
temperature calibration
section
Pressure calibration
section
Current firmware
version
Time server setup
nist.time.gov
Server URL:
Time Zone:
0:00
ADVANCED page
SETUP
Temperature
o
C
Indoor
Current offset: 1
Outdoor
Current offset: -9
CH 1
Current offset: 2
CH 2
Current offset: 3
CH 3
Current offset: 1.2
CH 4
Current offset: -0.2
CH 5
Current offset: -20.1
CH 6
Current offset: 11.5
CH 7
Current offset: 0.2
Range: -20.0 ~ 20.0
o
C
-36.0 ~ 36.0
o
F (Default: 0.0)
Pressure
Absolute Pressure Offset:
Relative Pressure Offset:
Setting Range:
-560~ 560hpa / -16.54 ~ 16.54inHg / -420 ~ 420mmHg
*Rain gain:
*Wind speed gain:
*Wind direction:
*UV gain:
*Light gain:
* Depends on the model
Firmware version: 1.00
" icon will
ADVANCED
Humidity %
Current offset: -5
Current offset: 10
Current offset: -5
Current offset: -2
Current offset: -2
Current offset: -5
Current offset: -3
Current offset: -10
Current offset: -3
Range: -20 ~ 20
(Default: 0.0)
hpa
Current offset: -3
(Default: 0)
Current offset: 10
(Default: 0)
Current gain: 0.85
Range: 0.5 ~ 1.5(Default: 1.00)
Current gain: 0.75
Range: 0.5 ~ 1.5(Default: 1.00)
Current offset: 2
o
Range: -10 ~ 10(Default: 0
o
)
Current gain: 1.1
Range: 0.01 ~ 10(Default: 1.00)
Current gain: 1.1
Range: 0.01 ~ 10(Default: 1.00)
Browse
Upload
11
Outdoor and Ch 1~7 humidity
calibration section
Select setting unit
Current offset value is the value
that you set before to offset the
pressure reading.
The rain, wind speed, UV and Light
calibration use gain method. The
wind direction is +/- 10 offset.
The firmware update
function only available
in PC web browser
Need help?
Do you have a question about the C6075A and is the answer not in the manual?
Questions and answers