DMX2CC 6ch/12ch

Power-up sequence

After applying power to the Unit, it will perform a quick self test for correct
Output LED wiring and a proper voltage from the DC Power Supply. Each of these
tests is followed by corresponding messages on the LCD screen.

Power supply test

After power-up the following message is displayed on the LCD screen:
V1.2-DX
Firmware version
12x700mA
Number of channels and rated current
If voltage from the PSU (Power Supply Unit) is not in the allowed range, the unit
will not operate and the following message will be displayed:
PSU fail
PSU voltage is too low
10.4V
If the Power Supply Unit voltage that connected to the unit is in normal range,
the following message will be displayed:
PSU ok
PSU voltage is in range
48.0V
Please refer to the Technical Data Specifications to select the correct Power
Supply.

Device setup