Psu Selection Guidelines - ECUE DMX2CC Series Setup Manual

Table of Contents

Advertisement

DMX2CC 6ch/12ch

PSU Selection Guidelines

!
Please follow the PSU selection guidelines below
in order to select the correct power supply.
!
Use at least 15 AWG (1.5mm
connection.
!
It is highly recommended to connect all four
terminals of the power-in captive screw terminal.
!
Maintain correct polarity when connecting the
power supply. Failure to do so may cause damage
to the unit.
The PSU must be selected keeping in mind the maximum number of serial LEDs
per channel in the application, output cable type/length, and the power rating
needed to drive the LEDs at the desired current. The table below illustrates the
relationship between these variables.
No.of
Total
Recom.
Minimal PSU Power
LEDs
Vf of
PSU
in a
LEDs
voltage
series
(typ.)
@350mA
1
3.5V
24V
10W
2
7V
24V
18.8W
3
10.5V
24V
26.5W
6
21V
24V
50.3W
9
31.5V
36V
72.8W
12
42V
48V
92.6W
2
) for DC power-in
Minimal PSU Power
Rating for
Rating for
DMX2CC 6Ch
DMX2CC 12Ch
Dimmer
Dimmer
@700mA
@350mA
@700mA
20W
20W
40W
37.6W
37.6W
75.2W
53W
53W
106W
100.6W
100.6W
201.2W
145.6W
145.6W
291.2W
185.2W
185.2W
370.4W
11

Advertisement