2.2 Factory Menu

Name
Default
FAC
OFF
HOTKEY
WARM-
OFF
UP
ADC
>>
WHITE
>>
BALANCE
SHOP
DO
NVM RESET
DO
SET FAC CH
DO
Power On
LAST/STB
Mode
USB
UPDATE
SW NO.
OFF
Project
Name
SIACP
Version
Date
MS82MT-AP/LA Chassis Aliment procedure
Factory Menu
Description
Factory Menu shortcut button switch
The item must be disabled (OFF) after production
OFF: Normal mode. Display blue screen when no signal. Turn to
automatically standby mode if keep the signal unavailable over
15 minutes.
ON: Aging mode. Display snow dot when no signal. The set will not
turn to standby even if the unavailability of signal;press
'function'key to exit warm-up mode.
ADC calibration ( see details below)
White Balance Adjustment ( see details below)
It is crucial that the function is executed after production aim to clear
information of production process, ensure user cannot access to
Factory Menu after executing the item.
Restore default value except WB and ADC data.
Preset the channel table of factory. Option: HZ, WX, EGYPT-EL,
ALGERIA e.g. To preset the channel table of certain factory, firstly,
choose the corresponding factory name, then press OK button of
remote control and wait until the disappearance of Factory Menu,
ON: the set will power on after switching on power.
STB: the set will remain standby status after switching on power.
Last: the set will turn to the status in which it lies when last switching
off.
If without requirement from certain customer,
by default, the Setting should be Last for MS82S-AP and STB for
MS82S-LA
Upgrade software. Please see details below.
Version information of Main Software
Product model
Serial port remote control protocol
Release date and time of main software
PRELIMINARY INFORMATION ----- SUBJECT TO CHANGE
Status
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK