Defaulting
Full Default (All Codes)
Relay 1 Default (Relay 1 Codes Only)
Relay 2 Default (Relay 2 Codes Only)
Panel Codes Default (Panel Codes Only)
Wiring
Relay Indicators
ISSUE100.DOC
2 Channel Radio Interface
You may also teach a transmitter to operate both relays at once using just one
button on the transmitter. This however, is a two step operation. Firstly you
must teach the transmitter code to Relay 1 by holding down SW1 and then
pressing the transmitters button. Then you would teach the transmitter to
Relay 2 by holding down SW2 and then pressing the same button on the
transmitter that you used to teach Relay 1.
Now, when you push the button on the transmitter, both relays will operate.
You could even teach the transmitter to operate both relays, but to have Relay
1 as momentary operation and to have Relay 2 as a toggle operation. Simply
hold down both SW2 and SW3 when teaching the transmitters code to Relay 2.
When a relay that has a toggle attribute is in the latched state (on), if a
transmitter assigned to that same relay with a momentary attribute is activated,
the relay will toggle off when the button on the transmitter is released.
There are several different ways of defaulting the receiver board, depending on
what codes you need to remove. The table below lists the various options.
Default Required
To connect the 2 channel receiver to an BOSCH Solution control panel, wire
the receiver in parallel with the system codepad(s).
2 Channel Receiver
There are two red LED's located beside the terminal block on the receiver PCB
(LD1 and LD2). These are marked RL1 and RL2 on the PCB. When either
Relay 1 or Relay 2 are operating, the corresponding red LED will illuminate.
For the 2 channel radio interface to work correctly with the Solution range of
control panels, the feature of "Enable Radio Key/Keyswitch Interface"must be
enabled in the control panel that the 2 channel radio interface is connected to.
Refer to the control panels Installation manual for more information on
enabling this feature.
Bosch Security Systems Pty Limited
Remove power, hold down SW3 and power up
Remove power, hold down SW1 and power up
Remove power, hold down SW2 and power up
Remove power, hold down SW4 and power up
Table 1: Defaulting Procedures
Solution Panel
+12V
+12V
GND
GND
CLOCK
CLK
Table 2: Wiring Connections