Safety Devices - Fujitsu ASYG07KPCA Design & Technical Manual

Wall mounted type
Table of Contents

Advertisement

11. Safety devices

Type of
protection
Circuit protection
Current fuse (Main PCB)
Fan motor
Thermistor protection
protection
Terminal protection
program
(Discharge temp.)
Compressor
protection
Thermal protection
program
(Outdoor temp.)
Protection form
Activate
Reset
Activate
Reset
Activate
Reset
- 41 -
Model
AOYG07KPCA
AOYG09KPCA
250 V, 20 A
250 V, 5 A
85—122 °C
Fan motor stop
77—114 °C
Fan motor restart
110 °C
Compressor stop
After 7 minutes
Compressor restart
COOL or DRY: -15 °C
HEAT: -20 °C
Compressor stop
COOL or DRY: -10 °C
HEAT: -15 °C
Compressor restart
AOYG12KPCA