STOPPER INSTALLATION PROCEDURE
The Stopper can be installed two ways, "Locked" Mode (Stopper cannot be removed)
or "Unlock" Mode (Stopper is removable).
Locked Mode:
• Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. G.
• To install the stopper in "Locked" mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the rear of the
Sink. Rotate Stopper slightly if necessary so that the Stopper slides
all the way down.Fig. G.
• Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
• Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not "snap" into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
• Re-attach Cable. See "CABLE ADJUSTMENT PROCEDURE" in
Troubling Shooting Guide to complete installation. Stopper will be
in "Locked" mode and not be removable.

Unlocked Mode:

• Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. H.
• To install the stopper in "Unlocked" mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the front of the
Sink. Rotate Stopper slightly if necessary so that the Stopper slides
all the way down. Fig. H.
• Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
• Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not "snap" into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
• Re-attach Cable. See "CABLE ADJUSTMENT PROCEDURE" in
"Troublingshooting Guide" to complete installation. Stopper will be
in "Unlocked" mode and removable
.
Fig. J.
INSTALL CAM
- 7 -
LOOP TOWARD
REAR OF SINK
DRAIN
Locked Mode
(Vandal Proof)
2
LOOP TOWARD
FRONT OF SINK
DRAIN
Unlocked Mode
Fig. K.
CAM
INSTALL
CAM CAP
M96 5530 Re v. 1. 2
Fig. G.
Fig. H.