If a fire chamber temperature of 100°C is not reached
during firing up after 10 minutes, the air regulators
close completely again.
Attention:
The fire grate must normally be open during heating,
otherwise no primary air can enter into the fire cham-
ber.
→
Operating lever of fire grate pulled out
Fire grate operating lever
Shortened or extended combustion cycle
Since the operation of the chimney stove is primarily
dependent on the downstream chimney, you have
the possibility of reacting to different chimney condi-
tions by choosing different control curves.
Control curve 1:
→
Extended combustion cycle
→
Use, for example, with increased chimney
draught
→
Primary air shuts off after 10 minutes
→
Reduced secondary air supply
→
"Add fuel" signal if temperature drops
below 200 °C
Control curve 2:
→
Normal combustion cycle (factory setting)
→
Primary air shuts off after 15 minutes
→
"Add fuel" signal if temperature drops
below 280 °C
Control curve 3:
→
Reduced combustion cycle
→
Use for poor chimney draught
e.g. transition times with increased
outside temperatures
→
Primary air shuts off after 20 minutes
→
Increased secondary air supply
→
"Add fuel" signal if temperature drops
below 280 °C
Furthermore, there is the possibility of setting the
shut-off time of the primary air in a range of 5 to 60
minutes for the electronics in the operator menu.
The display of the electronics
Indicates automatic mode
→
Illuminates in intervals
Indicates instructions mode
→
Illuminates in intervals
Indicates air regulator setting is 100% open
11