Olsberg OEC Instruction

Electronic oven controller
Hide thumbs Also See for OEC:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Elektronische Ofensteuerung OEC
Anleitung
Instruction
Instructions
D
GB
F
Olsberg Efficiency Controller
Seite
2 - 7
Page
8 - 13
Page
14 - 20

Advertisement

Table of Contents
loading

Summary of Contents for Olsberg OEC

  • Page 1 Elektronische Ofensteuerung OEC Seite 2 - 7 Anleitung Page 8 - 13 Instruction Page 14 - 20 Instructions Olsberg Efficiency Controller...
  • Page 2: Table Of Contents

    Montage Diese elektronische Ofensteuerung OEC ist ein Spit- Lieferumfang zenprodukt moderner Feuerungstechnik. Mit dem OEC wird die Zufuhr der Verbrennungsluft während des gesamten Abbrandes automatisch ge- regelt. Durch das Schließen der Verbrennungsluftzufuhr am Ende des Abbrandes werden Wärmeverluste in den Standzeiten des Kaminofens vermieden.
  • Page 3 • Den Türkontaktschalter hinter der Fülltür auf der rechten Seite anschrauben. Das Anschlusskabel vorher durch die Montage- öffnung schieben. Temperaturfühler • Das Kabel der Stromversorgung durch die Durchführungstülle in der Rückwand unten schieben. Türkontaktschalter • Die Kabel, Stromversorgung und Fühlerkabel, •...
  • Page 4: Bedienung

    Stellmotor auf der Drehachse des Luftschieberhebels Der Startvorgang kann auch durch drücken der Taste aufschieben. R ausgelöst werden. Vorher die Drehachse mit dem Luftschieberhebel so ausrichten, dass der Stellmotor sich aufschieben Nach 15 Minuten Brenndauer fährt der Luftschieber lässt und und gleichzeitig in die Motor-Halteklammer in Abhängigkeit der erreichten Feuerraumtemperatur einschnappt.
  • Page 5 Primärluftschieber nochmals ganz aufgefahren wer- → Signal „Brennstoff nachlegen“ bei unterschreiten den. von 280 °C Wird die Fülltür im kalten Zustand betätigt ohne einen Desweiteren besteht die Möglichkeit im Betreiberme- Abbrand zu starten, so fahren die Luftschieber nach nü an der Elektronik die Schließzeit der Primärluft im 10 Minuten wieder zu.
  • Page 6 R drücken zur Bestätigung P + M gleichzeitig drücken zum Verlassen des Me- nüs Auswahl Regelkurve mit Untermenü tYP P drücken bis Anzeige PAS am Display erscheint R drücken = Anzeige 0 P drücken bis Anzeige – 2 erscheint (Codewort) R drücken = Anzeige PAS P drücken bis Anzeige tYP erscheint R drücken = Anzeige 2...
  • Page 7: Stromausfall

    R drücken zur Bestätigung Was ist, wenn? P + M gleichzeitig drücken zum Verlassen des Me- nüs ... der Kaminofen nicht richtig zieht? • Ist der Schornstein oder das Ofenrohr undicht? • Stromausfall Ist der Schornstein nicht richtig bemessen? Bei Stromausfall kann die Luftregulierung über den •...
  • Page 8: Foreword

    Fault Indications..........13 • What happens if? ........... 13 Foreword Installation This electronic oven controller OEC is a top product Delivery Contents of modern firing technology. In the OEC, the combustion air supply is automati- cally controlled during the entire combustion cycle.
  • Page 9 • Screw on the door contact switch behind the furnace chamber door on the right side. First, push the connection cable through the in- stallation opening. temperature sensor: • Push the cable of the power supply through the grommet in the back wall at the bottom. •...
  • Page 10: Operation

    Push the servo motor onto the rotation axis of the air After 15 minutes of burning, the air regulator changes regulator lever. to 50% or 40% depending on the fire chamber tem- First, align the rotation axis with the air regulator le- perature that has been reached.
  • Page 11 If a fire chamber temperature of 100°C is not reached during firing up after 10 minutes, the air regulators Furthermore, there is the possibility of setting the close completely again. shut-off time of the primary air in a range of 5 to 60 minutes for the electronics in the operator menu.
  • Page 12 Press R = 15 in display (for control curve 2) Set the desired value with P or M Press R to confirm Press P + M simultaneously to exit the menu Select control curve with sub-menu tYP Press P until PAS appears in the display Press R = 0 in display Press P until PAS appears in the display Press R = PAS in display...
  • Page 13: Power Failure

    Power failure What happens if? In the event of a power failure, the air can be regu- lated using the air regulator control lever..the chimney stove doesn't really draw? To do this, the gearbox of the servo motor must be •...
  • Page 14: Préambule

    Directives à respecter • Directives locales et directives relatives au droit de construction • Seul un spécialiste est habilité à procéder au branchement et à la mise en service de l'OEC. Patte de maintien moteur Douille d'écartement...
  • Page 15: Montage

    • Visser le contacteur de porte derrière la porte de remplissage sur le côté droit. Introduire au préalable le câble de raccordement à travers l'ouverture de montage. Sonde de température • Passer le câble de l'alimentation électrique à travers la douille de traversée dans la paroi ar- rière.
  • Page 16: Commande

    • Pour une nouvelle activation, appuyer sur les tou- Enfoncer le moteur de commande sur l'axe rotatif ches fonctionnelles P ou M. du levier de coulisseaux d'air. Aligner auparavant l'axe rotatif avec le levier de coulisseaux d'air de telle manière que le moteur La procédure de démarrage peut également être de commande se laisse enfoncer et qu'il s'en- activée en appuyant sur la touche R.
  • Page 17 Courbe de régulation 2 : Allumage → flambée normale (réglage en usine) Lors de l'allumage, disposer le combustible de la → fermeture de l'air primaire au bout de 15 minutes manière décrite dans le manuel du poêle à bois. → La procédure d'ouverture des coulisseaux d'air est signal «...
  • Page 18 Menu de l'exploitant Il est possible de procéder aux réglages suivants dans le menu de l'exploitant : • durée de fermeture de l'air primaire 5 à 60 min. • Sélection courbe de régulation 1 à 3 • Signal acoustique marche/arrêt •...
  • Page 19: Coupure De Courant

    Modifier la luminosité de l'écran avec le sous- Coupure de courant menu JAS La régulation d'air peut être effectuée au moyen du levier de coulisseaux d'air en cas de coupure de Appuyer sur P jusqu'à ce que PAS soit affiché sur courant.
  • Page 20: Qu'y A-T-Il Quand

    • Le besoin en chaleur est-il trop élevé ? • Le tube de gaz évacués est-il bouché ? • La cheminée ne tire-t-elle pas assez ? Olsberg Hermann Everken GmbH Hüttenstraße 38 • D - 59939 Olsberg Email: info@olsberg.com www.olsberg.com...