VOLUME COUNTER VERSION
Software rel.
2.3.x

Advertisement

Table of Contents
loading

Summary of Contents for ARAG Visio

  • Page 1 VOLUME COUNTER VERSION Software rel. 2.3.x...
  • Page 2: Table Of Contents

    CONTENTS ● Legend of symbols ..................... 3 INTRODUCTION ......................4 Product description ....................4 INTENDED USE ......................4 CONTENT OF THE PACKAGE ..................4 PRECAUTIONS ......................4 RISKS AND PROTECTIONS BEFORE ASSEMBLY ............ 5 Positioning ........................5 Power supply and sensor connection ................ 5 ASSEMBLY DIAGRAMS ....................6 CONTROLS IN THE MENU ................... 7 First switching on .......................
  • Page 3: Legend Of Symbols

    This manual is an integral part of the equipment to which it refers and must accompany the equipment in case of sale or change of ownership. Keep it for any future reference; ARAG reserves the right to modify product specifications and instructions at any moment and without notice.
  • Page 4: Introduction

    a n d Instruction manual connection cables (on CD-ROM) t o b e c o n n e c t e d Installation sheet to VISIO must be ordered separately. PRECAUTIONS • Do not aim water jets at the equipment. • Do not use solvents or fuel to clean the case outer surface. • Do not clean equipment with direct water jets.
  • Page 5: Risks And Protections Before Assembly

    Positioning 1) Set mounting rail in cabin and fasten it with the relevant screws (1), in a position where VISIO can be easily seen and at hands' reach, but away from any moving organs. 2) Secure VISIO to rail and push down until locked in place.
  • Page 6: Assembly Diagrams

    ASSEMBLY DIAGRAMS +12Vdc Counting abort Connection +12VDC (yellow wire) Counting abort Ground connection (green wire) Legend: 1) Power cable 2) Connection cable for single sensor 3) Flowmeter...
  • Page 7: Controls In The Menu

    CONTROLS IN THE MENU First switching on At first switching on, VISIO will run a guided procedure allowing user to set the device's basic settings. Press to scroll through items, to save and move on to next setting, or to go back to previous setting. WARNING: Before changing operating mode, make sure that all sensors / flowmeters are DISCONNECTED from the device.
  • Page 8: Controls In The Menu

    Controls in the menu In the following pages, according to the set operating mode, some menu items could slightly differ from the shown ones. SWITCHING ON A Press for 1 second; B Press the key to view the various values in extended mode, in a sequence (on display central part). Every time the device is switched on, it will shortly show a page with the name of device and software version. SWITCHING OFF A Press for 2 seconds. ACCESS TO SETUP MENU From the main page, press keys at the same time for 2 seconds to open the Setup Menu. SELECTION AND ACCESS TO MENU ITEMS A Press a few times to scroll through items (selected item is indicated by a black line); B Press to open the selected menu item. The three dots under an item indicate presence of another setup menu.
  • Page 9: Work Parameters

    EDITING A VALUE A Press to move through digits; B Press a few times to edit the highlighted digit; C Press to confirm. The display goes back to previous page; D Press to exit page without confirming modification. Edited value must fall within the range shown. Work parameters From the main page, press key for two 0.00 seconds to open Work Parameters menu, 0.00 and set values for Flow correction. l/min...
  • Page 10: Menu Structure

    MENU STRUCTURE...
  • Page 11: Preliminary Setup For Use

    PRELIMINARY SETUP FOR USE Flowrate alarms Set minimum and maximum flowrate thresholds for alarm message. 1) Open Alarm menu (Setup menu > Alarms). Minimum and maximum flowrate alarms are set in the same way. The display will show the current setting below the selected item. Press to edit the selected menu item. 2) To activate the alarm, press and at the same time until message OFF goes off and rate alarm value is displayed instead. Carry out the same procedure to disable alarm again. 3) Set alarm value: A) Press to move through digits. B) Press a few times to edit the highlighted digit. C) Press to save changes, or D) Press to quit the page without confirming changes.
  • Page 12: Sensors

    Sensors 1) Open Sensors menu (Setup menu > Sensors). The menu items displayed below change according to the set operation mode: when more items are available, select the desired one and press to edit it.
  • Page 13: Flowmeter Calibration

    Flowmeter calibration Due to the different system configurations (tubes, valves, etc.) rate reading could not be correct. It is therefore recommended to perform a spraying test. If measured value is different from actual value, change the rate constant through an automatic calibration procedure or manually calculate the constant. Automatic calibration Let a previously measured quantity of fluid go through the system or a quantity that could be measured through another system. The higher the quantity of fluid used to perform the calibration procedure, the more accurate the calibration. 1) Open automatic calibration menu (Setup menu > Sensors > Flowmeter > Auto Calibration). As soon as menu is open, the equipment is ready to start measuring with no further controls being required. 2) Start liquid flow in the system. The display will start showing the increasing value of the measured fluid quantity. As soon as fluid flow is over, the displayed counter will stop. 3) Now press . At the bottom of the display Stabilization, message will turn on and equipment will then show the page on the side. 4) Enter previously measured quantity of fluid: A) Press to move through digits. B) Press a few times to edit the highlighted digit. C) Press to complete the calibration procedure, or D) Press for 1 second to cancel the calibration procedure. Setting the fluid quantity actually passed through flowmeter during the calibration procedure.
  • Page 14 If equipment does not detect any flow after calibration is started (and displayed value remains 0), press to quit the calibration procedure without saving. If the device continues to detect flow after was pressed, the error message Stop flow!. will be displayed after a few seconds. As soon as flow is stopped, reading will stabilize, as per standard procedure. In case VISIO calculates a value out of the range that can be set by means of the manual calibration, the calculated value will not be set. Manual calibration In order to manually set rate constant, calculate and set suitable constant using the following formula: [quantity measured by equipment] x [constant indicated on flowmeter body] [actually sprayed quantity] 1) Open manual calibration menu (Setup menu > Sensors > Flowmeter > Man. calibration). Under Calibration menu, select Man. calibration, to view currently set constant value below the item. Press to edit the value. For flowmeter constant value, refer to the corresponding manual. 2) Set flowmeter constant value: A) Press to move through digits.
  • Page 15: Language

    Language Set the desired language. Open language setting menu (Setup menu > Options > Language). Options The display will show the current Language English setting below the selected item. Units of measurem. Display contrast Press to edit language. 1) Select a language through Language Česk Deutsch 2) Press to save, or to quit English Español without saving.
  • Page 16: Units Of Measurement

    Units of measurement Set unit of measurement for the values detected by the device. Flowrate units of measurement 1) Open instant rate unit of measurement setting menu (Setup menu > Options > Units of measurem. > Flowrate). The display will show the current setting below the selected item. Press to select flowrate unit of measurement. 1) Select a unit through 2) Press to save, or to quit without saving. Volume units of measurement 1) Open volume unit of measurement setting menu (Setup menu > Options > Units of measurem. > Volume). The display will show the current setting below the selected item. Press to select volume unit of measurement. 1) Select a unit through 2) Press to save, or to quit without saving.
  • Page 17: Display Contrast

    Display contrast Set display contrast. Open display contrast menu (Setup menu > Options > Display contrast). The display will show the current setting below the selected item. Press to edit the selected menu item. 1) Set a value through . Every time you press it, value will increase by 5% up to 100%. Use key to decrease value by 5%. 2) Press to save, or to quit without saving.
  • Page 18: Alarm Tones

    Alarm tones Enable/disable the alarm tones. Open alarm tones menu (Setup menu > Options > Alarm tones). The display will show the current setting below the selected item. Press to edit the selected menu item. 1) Set status through 2) Press to save, or to quit without saving. Keytones Enable/disable keytones. 1) Open keytones menu (Setup menu > Options > Keytones). The display will show the current setting below the selected item. Press to edit the selected menu item. 1) Set status through 2) Press to save, or to quit without saving.
  • Page 19: Display Settings

    Display settings The main page shows the display divided into three horizontal parts. Sectors identified with symbols and are the partial totalizers, which can be separately reset. The third value is instant flowrate. Every sector can be assigned the desired value. Partial totalizers Instant flowrate Open Display settings menu (Setup menu > Options > Display settings). Press to edit the selected menu item. 1) Select value through key. 2) Press to edit, or to quit without saving. 1) Set totalizer to the required value through key. 2) Press to save, or to quit without saving. Carry out the same procedure for the other 2 values.
  • Page 20: Operating Mode

    Operating mode Set required operating mode. Open operating mode menu (Setup menu > Options > Operating mode). The display will show the current setting below the selected item. Press to change the operating mode. 1) Select the required operating mode through 2) Press to save, or to quit without saving. WARNING: Once is pressed, the page on twhe side will be displayed. Before changing operating mode, make sure that all sensors are DISCONNECTED from the device. Press to confirm changes. Connect the sensors REQUIRED FOR THE SET OPERATING MODE.
  • Page 21: Setup Management

    Setup management VISIO settings can be loaded from or saved on a USB pen drive in order to reconfigure it if required, fix problems or set another VISIO with no need to repeat all manual operations. Once installation is completed, and VISIO operation has been checked, we recommend to save all settings onto a USB pen drive. To be able to use the following functions it is necessary to insert a USB pen drive in the relevant port at the bottom of VISIO. 1) Open Setup management menu (Setup menu > Setup management). Press to edit the selected menu item. Load setup Allows to select a configuration file saved in the USB pen drive and to set VISIO again. WARNING: By loading the SETUP.BIN file contained in the USB pen drive onto the VISIO, all current settings will be lost. 1) Select the desired control through key. 2) Press to confirm loading, or to quit without saving. The SETUP.BIN file can be loaded only if it is saved in the USB pen drive root directory. If setup download involves changing operating mode and using different sensors than the ones in use, make sure that all sensors are DISCONNECTED from the device. Press to confirm loading. Reconnect sensors.
  • Page 22 Save setup Allows saving VISIO configuration file on the USB pen drive: it will be possible to load it again any time the same settings need to be retrieved. 1) Select the desired control through key. 2) Press to confirm saving, or to quit without saving. If a SETUP.BIN file is already present in the USB pen drive root directory, the file will be overwritten.
  • Page 23: Test Menu

    Test menu This menu allows user to view some data and carry out an operation test of VISIO: - Firmware version: the display shows the firmware version installed. - Battery voltage: the display shows the power voltage of the device. Display test Display test checks the device display correct operation. 1) Open display test menu (Setup menu > Test > Display). Press to perform the test. All pixels on display are turned on. Press to go back to previous page. Keys test Keys test checks the device keys correct operation. Open keys test menu (Setup menu > Test > Keys). Press to perform the test. 1) Press any key and the corresponding display area will turn on. Press to quit: as soon as you acknowledge the switch-on on of the corresponding area on the display, device will go back to previous page.
  • Page 24 Sensors test Sensors test checks correct operation of the sensors connected to the device. Open sensors test menu (Setup menu > Test > Sensors). Press to perform the test. The display will show the current sensor reading below the selected item. 1) Several sensors could be displayed, depending on the set operating mode. In this case, select required sensor through 2) Press to quit.
  • Page 25: Use

    Start liquid flow in the system. The display will start showing the increasing value of the measured fluid quantity and instant flowrate. Press key several times to view a value in extended mode until value is on display central part. Partial totalizer reset To reset a totalizer you must view it in extended mode. Press key several times until value to be reset is at the central area of the display. Press key for two seconds. Totalizer resets. Symbol ------ indicates that flowrate or totalizer exceed maximum value that can be displayed. Totalizers have a floating point and show a maximum of 4 digits. Two decimals are shown up to 999.99. One decimal is shown after that and 0 decimals are shown when value reaches 10000. 21.84 l/min 21.84 l/min 21.84 l/min 21.84 l/min 999.99 1000.0 9999.9 10000 50.00 l 1050.0 l 10049 l 10050 l...
  • Page 26: Maintenance / Diagnostics / Repairs

    MAINTENANCE / DIAGNOSTICS / REPAIRS • Clean only with a soft wet cloth. • Do not use aggressive detergents or products. • Do not clean equipment with direct water jets. Troubleshooting FAULT CAUSE REMEDY Check power cable No power supply connections VISIO is off or does not switch on Device is OFF Press the ON key Check displayed data Wrong setup setup VISIO shows wrong data Sensor fault Contact the nearest Assistance Center VISIO fault Filling pump (if any) does Pump Stop Module not Check power supply not start powered connection END OF LIFE DISPOSAL Dispose of the system in compliance with the established legislation in the country of use.
  • Page 27: Technical Data

    TECHNICAL DATA Device technical data Description VISIO Display Graphic LCD, 128 x 64 pixels, back-lighting Power supply voltage 9 ÷ 16 Vdc Protection against short-circuit • Protection against polarity inversion • Max. frequency 1.2 KHz Analog inputs 4 ÷ 20 mA Digital output - Max current 100 mA Maximum power input (with no 160 mA sensors connected) -20 °C ÷ 70 °C Operating temperature -4 °F ÷ +158 °F -30 °C ÷ 80 °C Storage temperature -22 °F ÷ +176 °F Size 126 x 79 x 66 mm Weight 245 g...
  • Page 28: Setup Menu

    Setup menu Data Min. Max. Default UoM Notes Flowmeter Calibration 10000 pls/l Alarm can be disabled by setting Min flowrate 1000 l/min. value to "OFF" Alarms Alarm can be disabled by setting Max flowrate 1000 l/min. value to "OFF" Display Contrast Available languages: Italiano, English, Español, Português, Language English Français, Deutsch, Cesky, Polski, Русский, Magyar, Options Flowrate units of Available units of measurement: l/min. l/min. measurement l/min, GPM, m Volume units of Available units of measurement: liters measurement l, gal, m...
  • Page 29: Guarantee Terms

    GUARANTEE TERMS ARAG s.r.l. guarantees this apparatus for a period of 360 days (1 year) from the date of sale to the client user (date of the goods delivery note). The components of the apparatus, that in the unappealable opinion of ARAG are faulty due to an original defect in the material or production process, will be repaired or replaced free of charge at the nearest Assistance Center operating at the moment the request for intervention is made. The following costs are excluded: disassembly and reassembly of the apparatus from the original system; transport of the apparatus to the Assistance Center. The following are not covered by the guarantee: damage caused by transport (scratches, dents and similar); damage due to incorrect installation or to faults originating from insufficient or inadequate characteristics of the electrical system, or to alterations resulting from environmental, climatic or other conditions; damage due to the use of unsuitable chemical products, for spraying, watering, weedkilling or any other crop treatment, that may damage the apparatus; malfunctioning caused by negligence, mishandling, lack of know how, repairs or modifications carried out by unauthorized personnel; incorrect installation and regulation; damage or malfunction caused by the lack of ordinary maintenance, such as cleaning of filters, nozzles, etc.; anything that can be considered to be normal wear and tear. Repairing the apparatus will be carried out within time limits compatible with the organizational needs of the Assistance Center. No guarantee conditions will be recognized for those units or components that have not been previously washed and cleaned to remove residue of the products used; Repairs carried out under guarantee are guaranteed for one year (360 days) from the replacement or repair date. ARAG will not recognize any further expressed or intended guarantees, apart from those listed here. No representative or retailer is authorized to take on any other responsibility relative to ARAG products. The period of the guarantees recognized by law, including the commercial guarantees and allowances for special purposes are limited, in length of time, to the validities given here. In no case will ARAG recognize loss of profits, either direct, indirect, special or subsequent to any damage. The parts replaced under guarantee remain the property of ARAG. All safety information present in the sales documents regarding limits in use, performance and product characteristics must be transferred to the end user as a responsibility of the purchaser.
  • Page 30 Via Palladio, 5/A 42048 Rubiera (RE) - Italy P.IVA 01801480359 Dichiara che il prodotto descrizione: Visualizzatore multifunzione modello: Visio serie: 4670610 risponde ai requisiti di conformità contemplati nella seguente Direttiva Europea: 2004/108/CE e successive modificazioni (Compatibilità elettromagnetica) Riferimenti alle Norme Applicate: UNI EN ISO 14982 (Macchine agricole e forestali - Compatibilità...
  • Page 31 Only use genuine ARAG accessories or spare parts to make sure manufacturer guaranteed safety conditions are maintained in time. Always refer to ARAG spare parts catalog. 42048 RUBIERA (Reggio Emilia) - ITALY Via Palladio, 5/A Tel. +39 0522 622011 Fax +39 0522 628944 www.aragnet.com...