(4.1 Mm) Unpacking; Product Features; General Safety Information - ProFitter LPFA40PF Operating Instructions & Parts Manual

Propane construction heater
Table of Contents

Advertisement

ProFitter
Operating Instructions & Parts Manual
TM
ProFitter
Heater
Unpacking
1. Remove all packing items applied to
heater for shipment. Keep plastic cover
caps attached to inlet connector and
hose/regulator assembly for storage.
E
2. Remove all items from carton.
N
3. Check all items for shipping damage.
G
If heater is damaged, promptly inform
L
dealer where you purchased the heater.
I

Product Features

S
- Portable, stable and fully assembled.
H
- Wind resistant and rain protected.
- Continuous spark ignition or piezo
spark ignition.
- 100% safety shut-off system.
- Adjustable input ratings.
PROPANE INFORMATION
The Propane (LP) gas tank must also be
equipped with the following:
- A collar to protect the gas valve.
- A shut-off valve terminating a Propane
gas cylinder valve outlet as specified
in the American National Standard for
Compressed Gas Cylinder Valve Outlets
and Inlet Connections.
- A safety relief valve having direct
communications with the vapor space
of the tank.
- An arrangement of vapor withdrawal.
NOTE: The Propane (LP) gas pressure
regulator and hose assembly supplied
with this heater must be used without
alteration.

General Safety Information

IMPORTANT: Be sure to read and
understand all cautions and warnings,
before operating this heater. Keep
this instruction manual for future
reference, and use it as a guide to safe
and proper operation of the heater.
Various precautions appear throughout
this manual. Please review and pay
close attention to them. Below is an
explanation of the various levels of
caution required while operating this
heater.
DANGER
Indicates an im minen tly
hazardous situation
which, if not avoided, WILL result in death
or serious injury.
WARNING
Indicates a poten tially
hazardous situation
which, if not avoided, COULD result in
death or serious injury.
For Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:30 am - 4:30 pm CST
Propane Construction
TM
CAUTION
which, if not avoided, MAY result in minor
or moderate injury.
WARNING
COMPLY WITH THE PRECAUTIONS AND
INSTRUCTIONS PROVIDED WITH THIS
HEATER, CAN RESULT IN DEATH, SERIOUS
BODILY INJURY AND PROPERTY LOSS,
OR DAMAGE FROM THE HZARARDS OF
FIRE, EXPLOSION, BURN. ASPHYXIATION,
CARBON MONOXIDE POISONING, AND/OR
ELECTRIC SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND
AND FOLLOW THE INSTRUCTIONS SHOULD
USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER
INFORMATION SUCH AS AN INSTRUCTION
MANUAL, LABELS, ETCETERA, CONTACT THE
MANUFACTURER.
WARNING
EXPLOSION HAZARD, KEEP SOLID
COMBUSTIBLES, SUCH AS BUILDING
MATERIALS, PAPER OR CARDBOARD, A SAFE
DISTANCE AWAY FROM THE HEATER AS
RECOMMENDED BY THE INSTRUCTIONS.
NEVER USE THE HEATER IN SPACES WHICH
DO OR MAY CONTAIN VOLATILE OR
AIRBORNE COMBUSTIBLES, OR PRODUCTS
SUCH AS GASOLINE, SOLVENTS, PAINT
THINNERS, DUST PARTICLES OR UNKNOWN
CHEMICALS.
WARNING
This product and the fuels used to
operate this product (liquid propane),
and the products of combustion of
such fuels, can expose you to chemicals
including benzene, which is known to
the State of California to cause cancer
and reproductive harm.
For more information go to
www.p65Warnings.ca.gov
WARNING
requires that the heater is positioned
so that it is protected against any possible
damage by a moving vehicle, etc. It must be
positioned so that the base of the heater is
no less than 18 in (450 mm) above the
garage floor or 8 ft (2450 mm) in repair
garages. The heater must be placed on a
stable surface. Do not place it on a chair,
ladder, etc. Raising the heater will reduce
BUT NOT eliminate the possibility of lighting
the vapor of any flammable liquids which
may be improperly stored or accidentally
LPFA40PF, RMC-FA60PF, RMC-FA125PF, RMC-FA150PF
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
Indicates a poten tially
spilled. If the smell of gasoline is present,
hazardous situa tion
DO NOT operate this heater until the area
has been properly ventilated.
GENERAL HAZARD
WARNING
FAILURE TO
The heater is designed and approved
for use as a construction heater
under ANS Z83.7 CSA 2.14. It is hard
to anticipate every use which may
be made of this heater. CHECK WITH
YOUR LOCAL FIRE SAFETY AUTHORITY
IF YOU HAVE QUESTIONS ABOUT
APPLICATIONS.
Other standards govern the use of fuel
gases and heat producing products in
specific applications.
Your local authority can advise you
about these.
FIRE, BURN,
IMPORTANT: READ THIS USER'S
INHALATION, AND
MANUAL CAREFULLY AND
COMPLETELY BEFORE TRYING TO
OPERATE OR SERVICE THIS HEATER.
IMPROPER USE OF THIS HEATER CAN
CAUSE SERIOUS INJURY OR DEATH
FROM FIRE, EXPLOSION AND CARBON
MONOXIDE POISONING.
This is a direct-fired forced air
construction heater for either indoor
construction or outdoor use. Its
intended use is primarily the temporary
heating of buildings or structures under
construction, alteration or repair. All
the products of combustion generated
by the heater are forced through the
heater and released into the area
being heated. This heater operates
at approximately 98%+ combustion
efficiency but still produces a small
amount of carbon monoxide. Humans
Using this heater in a
can tolerate small amounts of carbon
residential garage
monoxide for short periods. Carbon
monoxide can build up in a heated
space and failure to provide adequate
ventilation could result in poisoning or
death.
For either indoor or outdoor use.
Adequate ventilation shall be provided
in accordance with OSHA 29 CFR
1926.154, Safety Requirements
for Temporary and Portable Space
2
Not for home or rec­
WARNING
reational vehicle use.
www.ghpgroupinc.com

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rmc-fa60pfRmc-fa125pfRmc-fa150pf

Table of Contents