Download Print this page

Minimum Airflow By Heater Capacity; Auxiliary Heat Control Static Pressure Drop Factors; Available Power Cable - LG ANEH033B1 Installation Manual

Auxiliary heat control

Advertisement

Included Items

Minimum airflow by heater capacity

Capacity
(kBtu/h (RT))
12(1.0)
18(1.5)
24(2.0)
30(2.5)
36(3.0)
42(3.5)
48(4.0)
54(4.5)
Capacity
(kBtu/h (RT))
18(1.5)
24(2.0)
36(3.0)
42(3.5)
48(4.0)
!
CAUTION
Do not use less than minimum airflow.
There is risk of fire or damage to the product.

Auxiliary Heat Control Static pressure drop factors

Heater Capacity(kW)
0
5
10
15
20
If the Auxiliary Heat Control has been installed, then the ESP value has to be set.
For every increase in static pressure by 0.01 inWC, the ESP value should be increased by 1.
If the setting ESP value is inappropriate, the provided safety device will turn off the heater
according to the airflow.
* in.wc = inch Water Column, inAq

Available power cable

CAPACITY
MODEL
POWER SUPPLY
(kW @ 208/230 V)
ANEH033B1 208/230, 60 Hz, 1 Ph
2.46 / 3
ANEH053B1 208/230, 60 Hz, 1 Ph
4.1 / 5
ANEH083B2 208/230, 60 Hz, 1 Ph
6.56 / 8
ANEH103B2 208/230, 60 Hz, 1 Ph
8.2 / 10
ANEH153B2 208/230, 60 Hz, 1 Ph
12.3 / 15
ANEH230B2 208/230, 60 Hz, 1 Ph
16.4 / 20
<Knockout diameter>
6 Auxiliary Heat Control
3
5
380
380
480
480
480
480
630
630
900
900
1 000
1 000
1 000
1 000
1 300
1 300
3
5
480
480
480
480
900
900
1 000
1 000
1 000
1 000
Multi V
Static pressure drop (in, wc)
0
-0.01
-0.02
-0.04
-0.06
HEATER AMPS.
(Amps @ 208/230 V)
DUAL CIRCUIT
SINGLE
SINGLE
CIRCUIT
CIRCUIT
L1,L3
L2,L4
11.8 / 13
-
-
14.8 / 16.3
19.6 /21.7
-
-
24.5 / 27.1
31.6 / 34.8
-
-
40 / 43.5
39.3 / 43.5
-
-
49.1 / 54.3
-
20.7 / 21.7 41.8 / 43.5
-
39.4 / 43.5 39.4 / 43.5
7/8 inch
(22.2 mm)
1-23/64 inch
(34.5 mm)
1-23/32 inch
(43.7 mm)
Multi V
Heater Capacity (kW)
8
380
Not available Not available Not available
480
480
630
900
1 000
1 000
1 000
1 000
1 300
1 300
Single & Multi
Heater Capacity (kW)
8
480
480
900
1 000
1 000
1 000
1 000
Heater Capacity(kW)
0
3, 5
8, 10
15
20
MINIMUM CIRCUIT AMPS.
CIRCUIT BREAKER
(Amps @ 208/230 V)
(Amps @ 208/230 V)
DUAL CIRCUIT
SINGLE
CIRCUIT
L1,L3
L2,L4
L1,L3
-
-
20 / 20
-
-
30 / 30
-
-
50 / 50
-
-
60 / 60
-
25.9 / 27.2 52.3 / 54.3
-
30 / 30
-
49.2 / 54.3 49.2 / 54.3
-
60 /60
10
15
480
Not available Not available
480
Not available Not available
630
Not available Not available
900
900
1 000
1 000
1 300
10
15
480
Not available Not available
480
Not available Not available
900
900
1 000
1 000
Single & Multi
Static pressure drop (in, wc)
Single & Multi (Downflow)
-0.01 (-0.01)
-0.02 (-0.01)
-0.03 (-0.01)
-0.04 (-0.01)
POWER CABLE
(AWG)
DUAL CIRCUIT
DUAL CIRCUIT
SINGLE
CIRCUIT
L2,L4
L1,L3
L2,L4
-
-
10 / 10
-
-
-
10 / 10
-
-
-
6 / 6
-
-
-
6 / 6
-
60 / 60
-
10 / 10
6 / 6
60 /60
-
6 / 6
6 / 6
(Unit: CFM)
20
900
1 000
1 000
1 300
(Unit: CFM)
20
900
1 000
1 000
0 (0)
SIZE OF
KNOCKOUT
CONDUIT
DIAMETER
(inch(mm))
(inch(mm))
-
1/2 (21.3)
7/8 (22.2)
-
1/2 (21.3)
7/8 (22.2)
-
1 (33.4) 1-23/64 (34.5)
-
1 (33.4) 1-23/64 (34.5)
1-1/4(42.3) 1-23/32 (43.7)
1-1/4(42.3) 1-23/32 (43.7)