MODULES OF 4 OR 6 LOGIC INPUTS
ÉTUDES ET RÉALISATIONS
TPIs 4T
ÉLECTRONIQUES / INSTRUMENTATIONS / AUTOMATISME
TPIs 6T
Route de Brindas - Parc d'activité d'Arbora - N°2
69510 - Soucieu en Jarrest
FRANCE
version 02.02
Tél. 04 72 31 31 30 - Fax 04 72 31 31 31
Tel. Intern. 33 4 72 31 31 30 - Fax Intern. 33 4 72 31 31 31
Software SlimSet
User handbook
http: //www.ardetem.com - e-mail: info@ardetem.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TPIs 4T and is the answer not in the manual?

Questions and answers

Summary of Contents for ARDETEM TPIs 4T

  • Page 1 02.02 Tél. 04 72 31 31 30 - Fax 04 72 31 31 31 Tel. Intern. 33 4 72 31 31 30 - Fax Intern. 33 4 72 31 31 31 Software SlimSet User handbook http: //www.ardetem.com - e-mail: info@ardetem.com...
  • Page 2: Table Of Contents

    Summary UE conformity declaration 1 . INTRODUCTION 1.1 General features 1.2 Electrical features of the inputs 1.3 Functions 2 . CONFIGURATION OF THE NETWORK DIMENSIONS - MOUNTING 4 . CONNECTINGS...
  • Page 3: Ue Conformity Declaration

    Before any installation or maintenance work, make sure the power supply Name: Measure concentrator of the instrument is cut. TPIs 4T Type: This symbole indicates that the module is protected by a double or TPIs 6T reinforced isolation.
  • Page 4: Introduction

    Installation in division 2 cFMus They are available in 6 models: TPIs 4T 5V: 4 logic inputs of the type «logic 5V» insulated from one another Operating temperature ........-25°C to +70°C TPIs 4T 24V: 4 logic inputs of the type «logic 24V» insulated from one another TPIs 4T CO: 4 logic inputs of the type «contact»...
  • Page 5: Electrical Features Of The Inputs

    Mode toggle: at each activation of the logic input, the status of the concerned measure will be reversed. The minimum duration of the pulse must be 50ms. • TPIs 4T 5V: 4 logic inputs of the type «logic 5V» insulated from one Measure ‘1’ another value low level <...
  • Page 6 • Mode monostable: Time lapse: A time lapse can be programmed on each logic input (t max = 3600 sec., resolution 0.1 sec.) This time lapse can be either on switching to 1, or on switching to 0, or in both cases for the modes level and toggle. For the mode monostable this is possible only on switching to 1.
  • Page 7: Configuration Of The Network

    Type of the 2. CONFIGURATION OF THE NETWORK number instrument TPIs 4T TPIs 6T First start by launching the configuration software SlimSet. Status logic input n°1 The purpose is to define your network using the software. Status logic input n°2 Status logic input n°3...
  • Page 8: Dimensions, Mounting

    ‚ 3. DIMENSIONS, MOUNTING Assembling of the footings on the rail Dimensions:..........7.2 x 114 x 114 mm Housing: ..........self-extinguishing of PBT Terminals: ..........screwed connections (2.5mm², flexible or rigid) Screw thread .......... M3 BEWARE: Max. tightening torque......0.5Nm / 4.5in.lbs Min.
  • Page 9 • INSTALLATION IN DIVISION 2 (cFMus) • INSTALLATION IN AREA 2 (IECEx, ATEX) Class I, Div.2, Groups A,B,C,D T4 II3G Ex nA IIC T4 Gc (GB) The product must be installed by qualified staff, competent on the directives The product must be installed by qualified staff, competent on the directives and the regulation applicable to the division 2.
  • Page 10: Connectings

    4. CONNECTINGS TPIs 6T NPN 1 +24V Logic 1 TPIs 4T Contact 1 NPN 2 +24V Logic 2 NPN 1 NPN 2 +24V +24V Contact 2 Logic 2 Logic 1 NPN 3 +24V Contact 2 Contact 1 Logic 3 Contact 3...