MODULES OF 2 OR 4 ANALOG OUTPUTS
ÉTUDES ET RÉALISATIONS
TPIs 2A
ÉLECTRONIQUES / INSTRUMENTATIONS / AUTOMATISME
TPIs 4A
Route de Brindas - Parc d'activité d'Arbora - N°2
69510 - Soucieu en Jarrest
FRANCE
version 02.02
Tél. 04 72 31 31 30 - Fax 04 72 31 31 31
Tel. Intern. 33 4 72 31 31 30 - Fax Intern. 33 4 72 31 31 31
Software SlimSet
User handbook
http: //www.ardetem.com - e-mail: info@ardetem.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TPIs 2A and is the answer not in the manual?

Questions and answers

Summary of Contents for ARDETEM TPIs 2A

  • Page 1 02.02 Tél. 04 72 31 31 30 - Fax 04 72 31 31 31 Tel. Intern. 33 4 72 31 31 30 - Fax Intern. 33 4 72 31 31 31 Software SlimSet User handbook http: //www.ardetem.com - e-mail: info@ardetem.com...
  • Page 2: Table Of Contents

    Summary UE conformity declaration 1 . INTRODUCTION 1.1 General features 1.2 Features of the analog outputs 2 . CONFIGURATION OF THE NETWORK DIMENSIONS - MOUNTING 4 . CONNECTINGS...
  • Page 3: Ue Conformity Declaration

    Before any installation or maintenance work, make sure the power supply Name: Measure concentrator of the instrument is cut. TPIs 2A Type: This symbole indicates that the module is protected by a double or TPIs 4A reinforced isolation.
  • Page 4: Introduction

    1.1 General features 1. INTRODUCTION Listed • The TPIs 2A or 4A are modules of 2 or 4 insulated analog outputs, extra Installation in ATEX / IECEx area 2 narrow (7.2mm) designed for DIN rail mounting. Installation in division 2 cFMus •...
  • Page 5: Features Of The Analog Outputs

    3) Then programme each of the instruments, as well as the links between ins- truments: for each of the outputs of the output modules (TPIs 4R, TPIs 2A/4A ...) you must define the converter associated with this output, as well as the measure...
  • Page 6: Dimensions, Mounting

    Instructions for assembling on 35mm DIN rail according to EN 60715 4) Then transfer the programming of all the instruments of the bus. Important :  From the version 2.02 of the TPIs, it is possible to transfer the programming of Assembling of the TPIs directly from the master.
  • Page 7 ƒ „ • INSTALLATION IN DIVISION 2 (cFMus) Mounting Unmounting Class I, Div.2, Groups A,B,C,D T4 (GB) The product must be installed by qualified staff, competent on the directives and the regulation applicable to the division 2. It must be installed in an additional protecting enveloppe ensuring a protection at least of the type IP54.
  • Page 8: Connectings

    4. CONNECTINGS 0-20mA (Lr < 400Ω) 0-20mA (Lr < 400Ω) 0-10V 0-10V (Lr > 10KΩ) (Lr > 10KΩ) 24VDC ±30% communication LED «voltage presence» 0-20mA (Lr < 400Ω) 0-20mA (Lr < 400Ω) 0-10V 0-10V (Lr > 10KΩ) (Lr > 10KΩ) 24VDC ±30% communication...