IRRIGAMATIC ASSEMBLING INDEX INTRODUCTION................Page 01 Page 01 GUARANTEE................. VALIDITY OF THE GUARANTEE..............Page 01 SPEED SENSOR INSTALLATION..........Page 02 INSTALLING AN INDUCTIVE SPEED SENSOR ON THE PINION....Page 02 INSTALLATION OF THE MAGNETIC SPEED SENSOR WITH ROLLER..Page 02 3.2.1 ROLLER INSTALLATION.................Page 03 3.2.2...
Page 4
IRRIGAMATIC ASSEMBLING INDEX OUTER ALARM..................Page 08 S C H E M E ............Page 09 MODALITY OF USE...............
The manual contents and drawings are updated on printing date and refer to the features of the console they are supplied with. Matermacc s.r.l. reserves the right of updating and/or modifying them without prior notice. 2 GUARANTEE Upon delivery of your console please make sure your equipment has not been damaged during •...
IRRIGAMATIC ASSEMBLING 3. SPEED SENSOR !!! IMPORTANT !!! INSTALLATION Should it be necessary to position the 3.1 INSTALLING AN INDUCTIVE SPEED sensor on the crown, and should the crown SENSOR ON THE PINION not be perfectly circular, keep at higher distance.
IRRIGAMATIC ASSEMBLING 3.2.2 SENSOR INSTALLATION 4. INSTALLATION OF THE ADJUSTING VALVE Insert the sensor in the arm hole from the magneto • side and fix it with nut and check nut. 4.1 INSTALLATION OF THE BY-PASS Fix the spiralled cable to the roller arm and to the •...
IRRIGAMATIC ASSEMBLING 4.1.3 MOTOR REDUCTION GEAR !!! NOTE !!! INSTALLATION Insert the motor reduction gear in the valve shaft in Each valve is supplied with a manual such a way as to position the shaft plug in the motor adjustment dial that can be very useful reduction gear seat.
IRRIGAMATIC ASSEMBLING 5.1.1 DIAGRAM OF THE HYDRAULIC VALVE TO THE DRAIN SIDE SIGHT CONIC MOTOR SHUNT VALVE DRAIN DRAIN PIPE UNDER PRESSION HYDRAULIC VALVE SEES FRONTAL MOTOR PICTURE SHUNT VALVE DRAIN PIPE UNDER PRESSION DRAIN HYDRAULIC VALVE 5.2 SLOW- CLOSING VALVE The slow-closing valve consists of a motor-driven butterfly valve.
Page 10
IRRIGAMATIC ASSEMBLING VALVE 3" N° 4 VITI TE M8X25 VALVE 4"- 5" MOTORIDUTTORE N° 4 VITI TE M8X25 N° 4 RONDELLE M8 Fix the valve motor cable to the irrigator frame by straps or cable holders as far as the electronic gearcase. The valve motor cable bears a ring with number 5 and should be connected to gearcase connector 5.
IRRIGAMATIC ASSEMBLING INSTALLATION OF THE Fit the front and close the eletrocic console. END-OF-REWINDING Connect the power supply cable to a 12V SENSOR battery. The end-of-rewinding sensor is used to give the CHECK POLARITIES gearcase consent to start the procedures of end-of- CONNECT RED CABLE WITH POLE + work once the whole hose has been rewound.
IRRIGAMATIC ASSEMBLING 8.1.1 HOW TO CALIBRATE THE PRESSURE OPTIONS SWITCH 8.1 PRESSURE SWITCH Upon supply, pressure switch calibration is INSTALLATION random. To modify this value , remove the cover and act on the screw fitted on the pressure switch. The Irrigamatic machines are preset for direct Tighten the screw to increase pressure, loosen the connection to the electronic gearcase of a pressure screw to reduce it.
IRRIGAMATIC ASSEMBLING To scroll the menus just rotate the knob right or left. 10 MODALITY OF USE In order to select a menu just press the knob on the menu item that is being high lighted. 10.1 SWITCHING THE ELETRONIC The highlighting is obtained with an inverted CONSOLE ON...
IMPUT This access password is personalized for every manufacturer. It is entered by MATERMACC and To change the parameter value rotate the knob communicated only to the interested parties. until the value is highlighted and press the knob.
IRRIGAMATIC ASSEMBLING CAL. TYPE 12 CALIBRATION MANUAL Accessible only if a machine with roll on pinion has been selected in configuration. The calibration menu AUTOMATIC is password protected. Accessible only through the passwords reserved to the irrigator's manufacturer. 6. To select the calibration type you intend to carry out, highlight the required item and press the knob.
Page 17
IRRIGAMATIC ASSEMBLING To continue highlight by rotating the knob and then press it. NEXT The electronic console goes to layer 2; the following is displayed: CALIBRATION LAYER P P L ,0 3 Repeat the operations 7 through 9 to the last required layer.
IRRIGAMATIC ASSEMBLING 13 PARAMETERS RESERVED TO THE MANUFACTURER (PASSWORD:“CSTR”) Below please find the description of the configuration parameters for IRRIGAMATIC. Parameter Description Flow valve position. This parameter can also be 0 = inlet 1 = discharge displayed by the final user if he/she has a password for it Time out on flow valve openong if located at the inlet.
Page 19
IRRIGAMATIC ASSEMBLING Parameter Description Sensor of end of winding up. Flow valve position. D EV H Q W This parameter can also be displayed by the final user if SU H V H Q W he has a password for it: Sensor rain wind D EV H Q W SU H V H Q W...
Page 20
IRRIGAMATIC ASSEMBLING Parameter Description Conversion factor for the speed sensor for layer 6 if L P SXO V the sensor is the pinion mounted type mm/pulse. Length of layer 5. L P SXO V Conversion factor for the speed sensor for layer 5 if the sensor is the pinion mounted type mm/pulse.
Page 21
IRRIGAMATIC ASSEMBLING Parameter Description Diameter of the tube used for mathematical calibration. This parameter can also be displayed by the final user if he has a password for it: Length of the tube used for mathematical calibration. This parameter can also be displayed by the final user if he has a password for it: Correction factor used for mathematical calibration.
Need help?
Do you have a question about the IRRIGAMATIC PRO35 and is the answer not in the manual?
Questions and answers