Epson FX Series Product Support page 124

Hide thumbs Also See for FX Series:
Table of Contents

Advertisement

J
EPSON PRINTERS
TABLE 6-2. International Character Set Designation
Country
' SW1-6
1
SW1-7
1 SW1-8
U.S.A
ON
ON
1 ON
FRANCE
ON
ON
1 OFF
GERMANY
ON
OFF
i
ON
ENGLAND
'
ON
OFF
;
OFF
Countiy
1 SW1-6
SW1-7
swi-a
DENMARK
'
OFF
j
i
ON
1
ON
SWEDEN
1
OFF
ON
t
OFF
ITALY
1
OFF
1 OFF
ON
SPAIN
1
OFF
1
OFF
OFF
Setting of DIPSwitch No. 2
The DIP switch No. 2 includes the following 4 positions. A summary of the
functions of the respective DIP switch positions and their preset conditions
at the time of shipment are shown in table 6-3.
TABLE 6-3. Function and Conditions of DIP Switch No. 2 (FX 85/185/286)
Switch
Number
Function
OFF
ON
Factory
Setting
2-1
SLCT IN signal internally
fixed or not fixed
Not Fixed
Fixed
ON
2-2
Cut Sheet Feeder (option)
Invalid
Valid
OFF
2-3
FX 85/185
1" Skip-over perforation
Invalid
Valid
OFF
2-3
FX 286
1" Skip-over perforation
(ESOP mode)
Automatic CR on VT, LF, or
ESC J (IBM mode)
Invalid
With CR
Valid
NoCR
OFF
OFF
2-4
Automatic line feed
LF from host
Auto LF with CR
OFF
6-3
GENERAL
SW2-1:When the switch is ON, the printer is permanently in the
"selected" mode and no external software codes.
This setting affects pin 36 on the connector. Some computers
control this pin; if they do control the pin, the switch setting
should always be off.
SW2-2: Isset to ON only when installing the optional cut sheet feeder.
SW2-3 (FX 85. FX 185, and FX286 in the ESC/P mode)
This position is used to set the automatic skip-over perforation
function.
a) When this switch is set to ON, the 1-inch automatic skip over
perforation will be performed, i.e., the paper automatically
advances to the first line of the next page when the
remaining page length is 1 inch.
b) When this switch is set to OFF, the 1-inch automatic skip over
perforation will not be performed.
SW2-3 (FX 286 in the IBM mode)
a) When this switch is set to ON, a carriage return is not issued
when a line feed, vertical tab, or ESC J commands are
received.
b) When this switch is set to OFF, a carriage return is issued
when a line feed, vertical tab, or ESC J commands are
received.
SW2-4: Forces automatic IF with each CR.
When OFF, LF must be
provided via software as needed. This position is used to fix
AUTO FEED XT signal internally. The signal line is wired ORed
with pin No. 14 of the interface connector. To control pin No.
14. leave this DIP switch in the OFF position.