Specifications; Wiring Diagram - Desa SPC170-F Owner's Manual

Propane construction forced air heater, owner’s manual
Table of Contents

Advertisement

• 125,000 - 170,000 Btu/Hr (36.6 - 49.8 kW)
• Propane/LP Fuel
• Gas Supply Pressure to Regulator
Max - Bottle Pressure, Min - 5 psig (34.5 kPa)
• Gas Supply Pressure Regulator out
28" WC (6.97 kPa)
• Electrical Input - 115V, 60 Hz, 1Ø, 3a
• Direct Spark Ignition, interrupted type
• Primary Flame Control - Solid State
• High Temperature Control -
• Minimum Ambient Temp. Rating - 0 F (-17.8 C)
• Fuel Consumption - 5.8 - 7.9 lbs/hr (2.6 - 3.6 kg/hr)
• Fuel Orifice Port No. - 18
• Fuel Orifice Port Size - 0.80 mm
• Heated Air Output - 450 CFM (12.74 cu m/m)
Gas
Valve
Chassis
Ground
Motor
Thermostat
Line Cord
Chassis
Ground
10

SPECIFICATIONS

240 F (116 C)

WIRING DIAGRAM

CONNECTION DIAGRAM
Red
Green
White
Red
Red
Black
If any original wiring as supplied with the heater must
be replaced, it must be replaced with type AWG 105° C
Green
wire or its equivalent except as indicated
(*Type SF2 200. **SGI 250° C)
www.desatech.com
High Limit
Switch
Red
Black
White
Red
Chassis
Ground
Spark Plug
Line
Neut
Valve
Ground
Flame Control
113959-01B