Operating Parameters

The parameters are divided into "user parameters" and "protected operating
parameters," which can only be accessed by entering a code number.
User parameters
User parameters are operating parameters that you can change without entering
the code number: They are designated P00 to P30, P50, P51, P79, P86
Calling user parameters
To call user parameters immediately after switch-on:
Press the MOD key as long as
To call user parameters during operation:
Press and hold the CL key, then press MOD.
To go directly to a specific user parameter:
Press and hold the CL key, then press the first digit of the parameter number.
Release both keys and press the second digit.
Protected operating parameters
Before you can change protected operating parameters you must enter the code
number 95 148 through
off the position display.
To page through the parameter list
Forward paging: Press the MOD key.
Backward paging: Press the
By paging on, you automatically enter any change you've made in a parameter.
To change operating parameters
Increase the parameter value with the decimal point key, or
Decrease the parameter value with the minus key, or
Enter the numerical value for the operating parameter, e.g. for P79 ( SET blinks).
To correct your entries and show the parameter designation
Press the CL key.
To exit the operating parameters
Press ENT. All changes made become effective.
Operating Parameter List
Parameter
Meaning
Enter code number 95 148 to change a protected operating
parameter.
Display mode
Display
Angle display
Sorting mode
Classification
Lower sorting limit (ensure that P18 < P19)
Upper sorting limit (ensure that P19 > P18)
is visible in the display.
: They remain accessible until you switch
1 /
2 key.
Function / Effect
Decimal degrees
Degrees, minutes, seconds
+ / – 180°
360°
+ / –
Sorting on
Sorting off
Setting