Page 1
HEIDENHAIN Working with the measured ND 261 value display unit • Confirm entry value • Set display to value from Actual value and input display • Select datum P79 (P80!) (7-segment LED, • Page backward in 9 decades and sign)
The ND 261 is designed for use with HEIDENHAIN angle encoders with sinusoidal output signals: either ND 261 A for 11 µA (Id. Nr. 283 482 ..) or ND 261 V for 1 V (Id. Nr. 322 352 ..). These angle encoders have one reference mark or several distance-coded reference marks.
Page 3
Sorting and Tolerance Check Mode In this mode, the display value is compared with an upper and a lower limit value. Status indicators and the trigger signal outputs at the D-sub EXT connection (see that section) indicate whether the display value is less than the lower limit, greater than the upper limit, or between the two limit values.
Input the command STX (CTRL B) over the RXD input; or Input a latch command over the D-sub connection EXT. A connecting cable (to a PC, for example) is available from HEIDENHAIN (Id.-Nr. 274 545 ..); cable length up to 20 m (66 ft).
Page 5
D-Sub Connection EXT Danger to internal components! Voltage sources from external circuitry must conform to the recommenda- tions in EN 50178 for low-voltage electrical separation. Connect inductive loads only with a quenching diode parallel to the inductance. Use only shielded cable! Connect the shield to the connector housing.
Internal counter overflow Error while crossing over reference marks To clear the error message: Switch off the display unit. Should any of these error codes recur, contact your HEIDENHAIN service agency Offset compensation values for encoder signals have been erased: contact your HEIDENHAIN service agency.
Operating Parameters The parameters are divided into “user parameters“ and “protected operating parameters," which can only be accessed by entering a code number. User parameters User parameters are operating parameters that you can change without entering the code number: They are designated P00 to P30, P50, P51, P79, P86 Calling user parameters To call user parameters immediately after switch-on: Press the MOD key as long as...
Page 8
Parameter Meaning Function / Effect Setting Display value Concurrent display, no freeze Display with measured Frozen display / update with signal value output Frozen/concurrent display Counting Normal ( Positive ) Direction Inverse ( Negative ) direction Angle subdivision Subdivision 400, 250, 200, 100, 80, 50, 40, 25, 20, 10, 8, 4, 2.5, 2, 1, 0.4, 0.2 Counting 0 - 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 0 mode...
Page 9
Parameter Settings for HEIDENHAIN Angle Encoders Model Display Sub- Count. Decim. step division mode places 11 µA / 1 V / RPD 486 3 600 one single 0.01° / ROD 1080 0.005° 0.001° ROD 250C/ROD 280C 9 000 one single 0.005°...
Page 10
Storage: – 30 °C to + 70 °C (– 22 °F to 158 °F) Rel. humidity Annual average: < 75%; maximum: < 90% Weight 1.5 kg DR. JOHANNES HEIDENHAIN GmbH Dr.-Johannes-Heidenhain-Straße 5 D-83301 Traunreut, Germany (0 86 69) 31-0 . 56 832...