Sabbath Mode
continued
The fan may or may not be running when the door is opened; however, this is not
a result of the user's actions.
There is a delay on all control changes (fans and compressor) while the door is
open. This includes any fan action as a result of doors opening.
After a power outage, the refrigerator will power back up in the Sabbath Mode.
The temperature settings of the refrigerator will remain as set prior to turning on
Sabbath Mode and will return to those setting after Sabbath Mode is turned off.
The door alarm is disabled.
All of the button actions on the dispenser will be ignored by the control during
Sabbath mode.
The dispenser auto fill ultrasonic sensors for 'Sensor fill' are disabled.
The water valve, auger motor and duct door motor are disabled.
The icemakers are inoperative during Sabbath Mode.
Door openings are not counted for adaptive defrost, so the user has no influence
on the defrost process.
The time between defrost cycles is fixed at 8 hours. The defrost heater
termination is controlled by temperature.