Falling Edge Sensitivity Configuration Registers

FallEdgeEnable(N )

This register enables monitoring of input lines of port N for falling edges, where N is the port
number in hexidecimal.
Ports can range from 0 to 11 (0x0 to 0xB), depending on your device. For each port,
Note
you must add an additional offset equal to 0x10 time the port number in hex.
Address Offset: 0x43 + 0x(N)0
Type:
Size:
Bit Map:
7
6
FEE(7)
FEE(6)
Bit
7–0
© National Instruments Corporation
Read-write
8-bit
5
4
FEE(5)
FEE(4)
Name
Description
FEE(<7..0>)
Write a 1 to a bit to enable monitoring for the
corresponding line.
Chapter 2
3
2
FEE(3)
FEE(2)
2-7
Static DIO Register-Level Programmer Manual
Register Map and Descriptions
1
0
FEE(1)
FEE(0)