Cooling System - Pilous ARG 200 plus Instruction Manual

Hide thumbs Also See for ARG 200 plus:
Table of Contents

Advertisement

4.9. Cooling System

The pump and the coolant tank, which are mounted in the machine base, are the basic elements of the cooling system. You can
remove the coolant tank without the pump. The coolant pump conveys the coolant via hoses, valves and guide heads to the saw
blade. The volume of the coolant is regulated by the valves on the guide heads. The coolant cools down and lubricates the saw blade
and flushes away metal chips. The pump switches on and off when the saw blade drive is started or shut down. There is a setting
container in the the coolant tank, which needs to be cleaned during regular checks depending on the material to be cut. It is important
that the pump is always immersed in the coolant that facilitates its cooling. If the level of the coolant gets too low during cutting,
the pump will be irreparably damaged.
There is an overflow opening in the coolant tank, ensuring the right volume of the coolant in order to prevent flooding of
the pump (danger of burning the pump). If you fill in too much coolant, it may leak under the saw.
When handling coolants, risks linked to hazardous substances cannot be avoided. Observe the manufacturer's and/or
your company's instructions and recommendations referring to safe coolant handling.
PUMP
OVERFLOW OPENING
SUPPLY HOSE
VALVE
MESH
COOLANT TANK
DRAINAGE HOSE
SETTING CONTAINER