2.2 Quick Start List for Platform

Follow these steps when using the TPA721 MSOP EVM with the TI plug-n-play
audio amplifier evaluation platform (see the platform user's guide, SLOU011,
for additional details). Numbered callouts for selected steps are shown in
Figure 2–1 and details appear in Chapter 3.
Platform preparations
1) Ensure that all external power sources are set to OFF and that the platform
2) Install a TPA721 MSOP module in platform sockets U3 and U4 for stereo
3) Use switch S2 to select or bypass the signal conditioning EVM (U1).
4) Set control signal Polarity jumper JP8 to Hi.
5) Set jumper JP6 to select the Mute control input (causes the TPA721 to
Table 2–2. Platform Jumper and Switch Settings for the TPA721 MSOP EVM
Notes:
Power supply
6) Select and connect the power supply:
Inputs and outputs
7) Ensure that signal source level is set to minimum.
8) Connect the audio source to left and right RCA phono jacks J3 and J5 or
9) Connect 8-Ω – 32-Ω speakers to left and right RCA jacks J7 and J9 or to
Power Up
10) Verify correct voltage and input polarity and set the external power supply
Platform LED2 should light indicating the presence of V
modules installed on the platform should begin operation.
11) Adjust the signal source level as needed.
power switch S1 is set to OFF.
operation (or a module in either U3 or U4 for single channel operation),
taking care to align the module pins correctly.
shut down if a plug is inserted into platform headphone jack J10).
EVM
JP6
JP7
TPA721
Mute
X
1) X = Don't care
2) Set S2 to ON when signal conditioning board is installed in U1; set S2
to OFF when no signal conditioning board is installed.
a) Connect an external regulated power supply set to a voltage between
2.5 V and 5.5 V to platform V
to observe marked polarity,
or
b) Install a voltage regulator EVM (SLVP097 or equiv.) in platform socket
U6. Install a 9-V battery in B1 or connect a 7 V – 12 V power source
to a platform V
power input J1 or J2 and jumper the appropriate
CC
power input (see platform user's guide).
stereo miniature phone jack J4.
stripped wire connectors J8.
to ON. If V
and an on-board regulator EVM are used to provide V
CC
set platform power switch S1 to ON.
Quick Start List for Platform
JP8
S2
S3
Hi
Note 2
X
power input connector J6, taking care
DD
, and the evaluation
DD
Quick Start
,
DD
2-3