6-14-3
Assembling
6-14-3-1 For EBH253 series
Fig. 6-14-3-1-1
[1] When Spiral spring pops out of Reel:
make a round wire a little smaller than its storage
·
part on Starter case,
then set Spiral spring into the round wire.
·
[2] Set Spiral spring into Starter case while
releasing Spiral spring from the wire.
Note: Apply Makita grease FA No.2 to the spring in
advance. (Refer to Fig. 5-1-1 in page 4.)
Round wire
Set Spiral
spring into a
wire.
Fig. 6-14-3-1-3
[4] Fit the end of Spiral spring into the
hook on the center of Starter case.
[5] Recover Recoil starter spring force by reversing the disassembly procedure shown in Fig. 6-14-1-1 in page 26.
[6] Do the following checks of the spring force before assembling Recoil starter assembly to the machine.
Note:
When you fall down Starter knob, it must stand up by the spring tension.
·
When you pull Starter knob to the full, Reel must be one and a quarter turned.
·
[3] If Spiral spring touches the center boss on Starter case, Reel cannot
be set properly, so separate the end of Spiral spring from the center
boss.
Touching
Center boss
Spiral spring
Fig. 6-14-3-1-4
Starter knob
29 / 40
Fig. 6-14-3-1-2
Separate