Page 4
NEXO released its first gradient subwoofer, the CD12, which has been complemented since then by CD18, GEO SUB and RS15. These have been quickly adopted worldwide as standards and are considered today as state-of-the-art subwoofers. This success is a consequence of proper cabinet design and optimized definition of phase relations through sophisticated DSP algorithms leading to high directional control and SPL output.
User Manual. Failure to do this exposes people to potential injury or death. Please check the web site nexo-sa.com for the latest update. Always consult qualified NEXO personnel if the device installation requires construction work and make sure to observe the following precautions: Mounting precautions choose mounting hardware and an installation location that can support 4 times the weight of the speaker system;...
Page 6
The recycling of materials will help to conserve natural resources. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product. Page 6 / 76 System Manual RS Series...
Please consult the NEXO web site (nexo-sa.com) for the latest software releases. • Available for Mac, iPad and iPhone, NEXO NeMo provides full remote control over a digital audio network from anywhere in the venue, thanks to an intuitive and graphically attractive user interface. NeMo is available on Apple App Store.
1(+) Right driver (+) Rear driver (+) 2(-) Left driver (-) Front driver (-) Driver opposite to connector panel 2(+) Left driver (+) Front driver (+) DIRECTIONAL MODE OMNI MODE Page 8 / 76 System Manual RS Series...
FOH (main lobe direction) Connector plate in Directional Mode Omni Mode: it is recommended to install the connector panel on the side opposite to the drivers (factory default configuration) Connector PLATE IN Omni Mode Page 9 / 76 System Manual RS Series...
RS GENERAL SET-UP INSTRUCTIONS Cabling NEXO recommends the exclusive use of multi-conductor cables to connect the system: the cable kit is compatible with all the cabinets, and there is no possible confusion between LF, MF and HF sections. Cable choice consists mainly of selecting cables of the correct sectional dimension (size) in relation to the load resistance and the cable length.
In addition, it provides mechanical information for all clusters in agreement with Structural Analysis Reports (available in the Help section): dimensions, weight, gravity centre position, forces, moments, working load and safety factor. NS-1 installation package includes all NEXO User Manuals, Structural Analysis Reports and Certificates PDF files. NS-1 is a freeware available on nexo-sa.com...
We include this section to remind you of safe practice when flying the RS system. Please read it carefully. However, user must always apply his or her knowledge, experience and common sense. If in any doubt, seek advice from your supplier or NEXO agent.
For fixed installations, wind loading has to be taken into account in accordance to the national standards. The RS Rigging System requires regular inspection and testing by a competent test centre. NEXO recommend that the system is load tested and certified annually or more frequently if local regulations require.
Mounting skids on the pole stand hole side defines a “RS15 LEFT”. In such a case, front grid must be removed, flipped over and reinstalled so that NEXO logo appears on the same side than the skids.
Position handles according to below drawing (vertical opening must be aligned with connector panel or owner’s plate) Insert the four washers and screws provided with the RST-FLPLATES15 kit and tight them (torque value must be 10 Nm minimum) INSTALLING RS15 FLYING PLATES AND HANDLES Page 19 / 76 System Manual RS Series...
Fill each screw hole with Loctite 243 or equivalent Position wheels according to below drawing Insert the 8 washers and 4 screws provided with the RST-WHEELS15 kit (see detail in below drawing) and tight them Page 20 / 76 System Manual RS Series...
The first RS15 must be locked to the RS15 dolly using four push-pins according to below drawing. Subsequent RS15s are stacked on top using four push-pins per additional cabinet to secure the assembly. Bumper is to be attached to the top cabinet. Page 21 / 76 System Manual RS Series...
Remove the four screws on each side of RS18 Insert Spacer between cabinet and Rigging plates Fill each screw hole with Loctite 243 or equivalent Tighten the 6 screws alternately, at the rate of 4 revolutions per screw Page 22 / 76 System Manual RS Series...
Page 23
Insert the 8 handles washers and screws and tight them INSTALLING PAINTED RS18 RIGGING PLATES IMPORTANT RS18 handles must not be used to fly RS18’s (through illegal use of straps for example) Page 23 / 76 System Manual RS Series...
Page 24
Remove the twelve screws on each side of RS18 Remove the four screws on each side of RS18 Fill each screw hole with Loctite 243 or equivalent Tighten the 6 screws alternately, at the rate of 4 revolutions per screw Page 24 / 76 System Manual RS Series...
Page 25
Insert the 8 handles washers and screws and tight them INSTALLING CARPETED RS18 RIGGING PLATES IMPORTANT RS18 handles must not be used to fly RS18’s (through illegal use of straps for example) Page 25 / 76 System Manual RS Series...
The first RS18 must be locked to the RS18 dolly using 4 push-pins according to below drawing; Subsequent RS18s are stacked on top using four push-pins per additional cabinet to secure the assembly. Bumper is to be attached to the top cabinet. Page 26 / 76 System Manual RS Series...
Never use other accessories – including push-pins - when assembling RS15 and RS18 cabinets than the ones provided by NEXO: NEXO will decline responsibility over the entire RS115 and RS18 accessory range if any component is purchased from different supplier.
Connect bumper to first RS15 flying system link plates; ensure quick release pins are properly locked Insert axis in centre hole and secure it with provided “R” clips Connect hoist hook to bumper axis and lift assembly so that RS15 is off the ground Page 30 / 76 System Manual RS Series...
Page 31
Additional rigging point configurations are available so that the RS15 bumper is always set horizontally. These rigging point positions are: 34mm behind geometrical center; 17mm behind geometrical center (requires flipping the bumper horizontally); 34mm ahead geometrical center (requires flipping the bumper horizontally). Page 31 / 76 System Manual RS Series...
Page 32
Connect second RS15 to first RS15 flying system link plates Ensure quick release pins are properly locked OMNI MODE DIRECTIONAL MODE / ALTERNATED DIRECTIONAL MODE / BACK TO BACK DIRECTIONAL MODE / FACE TO FACE Page 32 / 76 System Manual RS Series...
Page 33
Secure bumper with secondary safety steel. IMPORTANT The requirements for secondary safety systems vary with territories. However, the secondary safety steel MUST have a SWL equivalent or greater than that of the rigging system Page 33 / 76 System Manual RS Series...
Connect bumper to first RS18 flying system link plates by using 4 10x25mm quick release pins Ensure the 4 quick release pins are properly locked Connect hoist hook to bumper axis (see below) Page 34 / 76 System Manual RS Series...
Page 35
Lift assembly to sufficient height in order to connect a second RS18 Position and align second RS18 below assembly Remove the 4 quick release pins from the PARKING position so that sliding connector plate can be moved Page 35 / 76 System Manual RS Series...
Page 36
Insert the 4 quick release pins into the FLOWN position of second RS18 Ensure quick release pins are properly locked Flying subsequent RS18’s Repeat above steps for subsequent RS18’s Lift cluster up to defined rigging height Secure it horizontally to prevent rotation Page 36 / 76 System Manual RS Series...
Page 37
Do not attempt to make any change to the bumper rigging point once the cluster is lifted IMPORTANT The requirements for secondary safety systems vary with territories. However, the secondary safety steel MUST have a SWL equivalent or greater than that of the rigging system Page 37 / 76 System Manual RS Series...
Testing and Maintenance of the system General: please keep regular maintenance attention to the RS flying system in order to provide long and reliable service. NEXO recommends regular testing of loudspeaker rigging components, preferably using a suitable test rig coupled with a visual inspection.
Low frequency level on stage is therefore significantly reduced on stage, and in the neighbouring environment in open air venues. Because of their directional pattern, Gradient subwoofer are also less sensitive to room eigen modes. Page 39 / 76 System Manual RS Series...
Therefore, main axis efficiency must be orientated outwards (through use of delays or curving the array outward as in below figure). Such arrays must be experimented playing one side only to check Page 40 / 76 System Manual RS Series...
Page 41
However, it is essential to keep in mind that stereo subwoofer array design always leads to strong interferences in the centre alley vicinity (a couple of steps left and right of mixing position). A successful design requires minimizing the audience area over which these interferences occur, and therefore lots of on-site experimentation. Page 41 / 76 System Manual RS Series...
RS15s and RS18s arrays must be installed with bumper set horizontally and all cabinets at 0°. Design procedure should be in agreement with what has been described in the preceding section. See following section on Steered Arrays Page 42 / 76 System Manual RS Series...
50cm (20”) from the RS15 and RS18 side walls and drivers. In case of stereo configurations, NEXO recommends that speaker side is set outwards to minimize interference region in stereo designs. (ie “RS15s LEFT” should be installed Left and “RS15s RIGHT” should be installed Right).
“face to face” configuration has a -3 dB coverage which increases from 120° at 31.5 Hz to 180° at 100 Hz "ALTERNATED" CONFIGURATION "ALTERNATED" CONFIGURATION AT 100HZ “BACK TO BACK“ CONFIGURATION “BACK TO BACK” CONFIGURATION AT 100 HZ “FACE TO FACE“ CONFIGURATION “FACE TO FACE” CONFIGURATION AT 100 HZ Page 44 / 76 System Manual RS Series...
“face to face” configuration has a -3 dB coverage which increases from 90° at 31.5 Hz to 120° at 80 Hz “ONE SIDE" CONFIGURATION "ONE SIDE" CONFIGURATION AT 80HZ “BACK TO BACK“ CONFIGURATION "BACK TO BACK" CONFIGURATION AT 80HZ “FACE TO FACE“ CONFIGURATION "FACE TO FACE" CONFIGURATION AT 80HZ Page 45 / 76 System Manual RS Series...
A 10 RS18 cluster flown at 10m/30ft will provide a +/- 3dB pressure level deviation at 100Hz over an audience area 75m/200ft deep while maintaining 15 to 20dB attenuation on stage. 12 RS15 CLUSTER OVER 75M/200FT 10 RS18 CLUSTER OVER 75M/200FT Page 46 / 76 System Manual RS Series...
If the coverage is to be tilted up, then lower group delay should be set at 0ms and delay should progressively increase on upper pairs. Delay value for first group is always 0ms. Delay value for second group is Delay values for subsequent groups are 2, 3 etc… Page 47 / 76 System Manual RS Series...
104.4 117.0 128.7 7.3.3 Coverage result Below figure shows coverage control over distance with a “steering” delay sequence corresponding to a 15° tilt down. 12 RS15 CLUSTER OVER 75M/200FT, STEERED 15° DOWN Page 48 / 76 System Manual RS Series...
If the coverage is to be tilted up, then lower group delay should be set at 0ms and delay should progressively increase on upper pairs. Delay value for first group is always 0ms. Delay value for second group is Delay values for subsequent groups are 2, 3 etc… Page 49 / 76 System Manual RS Series...
3 RS18s DISTANCE (cm) 7.4.3 Coverage result Below figure shows coverage control over distance with a “steering” delay sequence corresponding to a 15° tilt down. 10 RS18 CLUSTER OVER 75M/200FT, STEERED 15° DOWN Page 50 / 76 System Manual RS Series...
Aligning RS with main system The NEXO TD Controllers factory presets are optimised to provide the best possible crossover between the RS15 and RS18 and other NEXO main systems. These crossover algorithms are defined for speaker acoustic reference points being aligned.
Angle (in radians) =3.142 x Angle (in degrees)/180 Computer – Laptop or Desktop PC running Windows 8 with the current version of NEXO NS-1 installed. It is not possible to configure a GEO tangent array properly without using NS-1. Note that, when NS-1 designs are prepared prior to arrival at the venue, it is often necessary to modify or update the design to accommodate special circumstances.
Play the same CD track on the MAIN system, on the SUB system, then on both: • inverting polarity on one of these outputs – MAIN or SUB - should always result in a massive difference near the crossover point. Page 53 / 76 System Manual RS Series...
TECHNICAL SPECIFICATIONS ECHNICAL PECIFICATIONS RS15 8.1.1 System specifications Omni Directional RS15 WITH NEXO TDCONTROLLER SETUP Frequency Response @-6 dB 35 Hz to 250 Hz 35 Hz to 150 Hz Sensitivity 1W@1m 105 dB SPL Nominal 103 dB SPL Nominal Peak SPL@1m...
Frequency response and impedance (dB) Level, Sound pressure Frequency (Hz) OC : Response C urve for 2.83Vrms at NX242 input Amplitude log Frequency (Hz) F: Omni Mode FC : C ardio Mode Page 55 / 76 System Manual RS Series...
TECHNICAL SPECIFICATIONS RS18 8.2.1 System specifications Directional Omni RS18 WITH NEXO TDCONTROLLER SETUP Frequency Response @-6 dB 29 Hz to 250 Hz 29 Hz to 150 Hz Sensitivity 1W@1m 105 dB SPL Nominal 103 dB SPL Nominal Peak SPL@1m 143 to 146 dB...
Need help?
Do you have a question about the RS Series and is the answer not in the manual?
Questions and answers