Download Print this page

Travis Industries 99000154 Manual page 3

For lopi sturbridge

Advertisement

3
Attach the wiring harness following the directions below (do not plug in the power cord at this time).
a
Remove one of the nuts holding
the blower in place. Insert the
screw through the eyelet on the
green ground wire and replace.
11/32" Nutdriver
b
Attach the two black wires
labeled "Snap Disk" to the
snap disk (orientation does
not matter).
c
Route the wires labeled "Valve
on/off" and "Solenoid" under
the burner pan to a location
near the gas control valve (they
are for the optional modulating
remote).
Page 3 of 4
d
Insert the molex connector on the power cord through the
hole on the blower cover and attach it to the molex
connector on the wiring harness. With the outer black
casing of the power cord 1" through the hole, install the
strain relief. The strain relief is best installed using pliers to
compress the two sides while pushing it into the hole.
Sturbridge Blower
(Part # 99000154)
f
Attach the two black wires labeled
"Rheostat" to the rheostat wires
(orientation does not matter).
4/8/04
e
Attach the black and white wires
labeled "Blower" to the blower
(orientation does not matter).
Do not plug
the heater in
until
installation is
complete.
Travis Industries, Inc.

Advertisement