Download Print this page

Travis Industries 99000154 Manual

For lopi sturbridge

Advertisement

Quick Links

Compatibility
• Lopi Sturbridge Cast Gas Stove
Packing List:
• Blower
• Blower Cover
• (4) Nuts & (4) Washers
• Rheostat Knob
Important Warnings
5
Turn the gas control valve to off and make sure the appliance has fully cooled prior to conducting service.
6
This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and
should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the
grounding prong from this plug.
Installation
1
Slide the thermodisk into the holder underneath the firebox.
Page 1 of 4
• Wiring Harness
• (4) Grommets with Spacers
• Remote Receiver Heat Shield (used only if using a remote)
Sturbridge Blower
(Part # 99000154)
• Snap Disk
• Power Cord
• Rheostat Control Rod
12/4/02
• Strain Relief
• 1/16" Hex Wrench
Snap Disk Bracket
(attached to stove)
Snap Disk
Travis Industries, Inc.

Advertisement

loading

Summary of Contents for Travis Industries 99000154

  • Page 1 Sturbridge Blower (Part # 99000154) Compatibility • Lopi Sturbridge Cast Gas Stove Packing List: • Blower • Blower Cover • Wiring Harness • Snap Disk • Power Cord • Strain Relief • (4) Nuts & (4) Washers • (4) Grommets with Spacers •...
  • Page 2 Sturbridge Blower (Part # 99000154) Attach the blower following the directions below. Slide the fan mounting plate into the slot on each of the rubber grommets. Fan Mounting Bracket (attached to stove) Rubber Grommet (with spacer) Blower Mounting Bracket Slide the rubber grommets (with spacers inserted inside) onto the fan mounting plate and attach using the included washers and nuts.
  • Page 3 Sturbridge Blower (Part # 99000154) Attach the wiring harness following the directions below (do not plug in the power cord at this time). Remove one of the nuts holding the blower in place. Insert the screw through the eyelet on the green ground wire and replace.
  • Page 4 Sturbridge Blower (Part # 99000154) Attach the blower cover and rheostat control rod (and knob) following the directions below. Make sure all of the wiring is placed away from the blower impeller and the bottom of the burner. Use lock ties, if necessary, to ensure no wires are damaged.