Samsung AE040JXEDEH Service Manual page 49

Eco outdoor/hydro unit
Table of Contents

Advertisement

Troubleshooting for outdoor unit(con.)
If an error occurs during the operation, it is displayed on the outdoor unit PCB LED, both MAIN PCB and INVERTER PCB.
LED Display
No.
Red
Green
24
25
26
27
28
29
30
31
32
33
34
35
36
37
Samsung Electronics
Displayed
PCB Assy
Yellow
MAIN/INVERTER
Comp. wire missing error
MAIN/INVERTER
Current sensor error
DC-Ling voltage
MAIN
Sensor error
MAIN
EEPROM read/write error
MAIN
Outdoor EEPROM error
IPM(IGBT Module) or PFCM Temperature sen-
MAIN/INVERTER
sor Error
MAIN/INVERTER
PFC Overload Error
Input current
MAIN
sensor error
MAIN/INVERTER
IPM is over heated.
MAIN
GAS Leak error
Water inlet
MAIN
temperature sensor error
Water outlet
MAIN
temperature sensor error
Refriqerant gas inlet
MAIN
temperature sensor error
Mixing Valve Outlet
MAIN
temperature sensor error
Meaning
Check Comp. wire
Check Outdoor Inverter
PBA
Check Input
voltage
Check EEPROM
Check Outdoor EEPROM
date
Check Outdoor Inverter
PBA
Check Outdoor Inverter
PBA
Check Outdoor Inverter
PBA
Check indoor and outdoor
unit model
Check Water
inlet sensor
Check Water
outlet sensor
Check Gas
inlet sensor
Check Mixing Valve
Outlet sensor
Troubleshooting
Remarks
Error Code
E467
E468
E469
E470
E471
E474
E484
E485
E500
E554
E901
E903
E906
E916
 Off
 Blink
 On
51