Error Messages; Storage And Shipping; Checking The Firmware Version - RCBS 98941 Product Instructions

Matchmaster powder scale/dispenser
Hide thumbs Also See for 98941:
Table of Contents

Advertisement

ERROR MESSAGES

ERR01
Invalid uSr parameter value or use of undefi ned uSr
ERR02
Invalid input range. Example: attempt to select uSr 99
ERR03
Powder type not specifi ed
ERROR
Other error

STORAGE AND SHIPPING

Before storing or shipping the MatchMaster, please activate the transportation protection
mechanism by turning the screw at the side counter-clockwise, then removing it or leaving it
in a "popped out" state (see photo below). To do this, turn on MatchMaster and press zero key
while scale is counting down. Numbers displayed will be stable. Rotate transportation screw
counter-clockwise until numbers on the display are no longer stable, this informs the user the
protection mechanism is activated. If the screw is removed please be sure to keep the screw
with the unit for use next time. If the screw is missing, any M4x8 fl at head screw or round
head screw can be used. After activating the transportation protection mechanism, place
MatchMaster into its original package and ensure that it is stored at 4°F~122°F (-20°C ~50°C).

CHECKING THE FIRMWARE VERSION

Switch on MatchMaster and press [UNIT] key while counting down, and display will show
"02028". To check the main board's fi rmware, press [ZERO] and the display will show "XXX". The
main board's fi rmware version is 02028XXX. To check the touch board's fi rmware, press [ . ] (to
left from the number 0) The display will show "17005" and then "XXX". The touch board's fi rmware
version is 17005XXX.
Turn counter-clockwise
Protection activated
(screw popped out or
removed)