Pro1 Technologies ZDA250W Manual page 2

Zoning application

Advertisement

Installation / Wiring
1.
Drill a 3/4" hole in the supply duct at least
36" from heat exchanger/coil and before
the rst zone damper, in relation to
air ow.
Remove cover and Wire R and C to the
2.
24V equipment transformer. (with power
o )
Mount on supply duct, leaving covers o
3.
for linking procedure, if needed. (If
supplied in 2 Zone Kit it will already be
linked).
The Sensor must be powered with 24
4.
VAC. We recommend wiring it to the
equipment board.
Remember
Our Wireless Zoning System contains
selectable wireless communication.
Each component has a jumper switch
labeled FSK and ASK. Default setting: FSK.
All components must be set to the same
position for wireless communication.
This selectable communication option is
available to you in case you have a device
you are pairing with that only has the
ASK option.
Wireless Range
Range between the sensor and the Master Thermostat is approximately 100 feet with no
obstructions and approximately 50 feet in standard residential metal, brick, and concrete construction.
INSTALLATION & WIRING
Inside of Sensor
FSK/ ASK Switch
R
C
2