5. Warnings, alarms and troubleshooting

5.1. Warnings and alarms

Probes naming:
S1 = B6 = Low pressure meter sensor (suction pressure)
S2 = B3 = Low temperature sensor (suction temperature)
S3 = B7 = High pressure meter sensor (discharge pressure)
S4 = B4 = High temperature sensor (discharge temperature)
Code
Display description
AL1
Clock Board Fault compressor 1
AL2
Clock Board Fault compressor 2
AL3
Clock Board Fault compressor 3
AL4
Clock Board Fault compressor 4
AL5
Exended memory fault compressor 1
AL6
Exended memory fault compressor 2
AL7
Exended memory fault compressor 3
AL8
Exended memory fault compressor 4
AL9
Max discharge pressure compressor 1
AL10
Max discharge pressure compressor 2
AL11
Max discharge pressure compressor 3
AL12
Max discharge pressure compressor 4
AL13
Min suction pressure compressor 1
AL14
Min suction pressure compressor 2
AL15
Min suction pressure compressor 3
AL16
Min suction pressure compressor 4
AL17
Probe S1,S2,S3,S4 Alarms compressor 1
AL18
Probe S1,S2,S3,S4 Alarms compressor 2
AL19
Probe S1,S2,S3,S4 Alarms compressor 3
AL20
Probe S1,S2,S3,S4 Alarms compressor 4
AL21
Low superheat EVD compressore 1
AL22
Low superheat EVD compressore 2
AL23
Low superheat EVD compressore 3
AL24
Low superheat EVD compressore 4
Low evaporation temperature EVD
AL25
compressor 1 (LOP)
Low evaporation temperature EVD
AL26
compressor 2
Low evaporation temperature EVD
AL27
compressor 3
Veco S
Reset
Delay
Auto
0 sec
Warning
Auto
0 sec
Warning
Auto
0 sec
Warning
Auto
0 sec
Warning
Auto
0 sec
Warning
Auto
0 sec
Warning
Auto
0 sec
Warning
Auto
0 sec
Warning
Manual
0 sec
OFF compressor
Manual
0 sec
OFF compressor
Manual
0 sec
OFF compressor
Manual
0 sec
OFF compressor
Auto
0 sec
OFF compressor
Auto
0 sec
OFF compressor
Auto
0 sec
OFF compressor
Auto
0 sec
OFF compressor
Manual
60 sec
OFF compressor
Manual
60 sec
OFF compressor
Manual
60 sec
OFF compressor
Manual
60 sec
OFF compressor
Auto
0 sec
Warning
Auto
0 sec
Warning
Auto
0 sec
Warning
Auto
0 sec
Warning
Auto
0 sec
Warning
Auto
0 sec
Warning
Auto
0 sec
Warning
Action
There may be an issue with the battery
in the board, please check the battery
and if it's not working change it.
Check also connections.
Contact the closest Climma service
center
Discharge pressure reading is more
then the allowed value therefore the
systems shuts off to keep the
compressor safe. Check the pressure
values registered in the log at the time
of the error.
Check the sea water pump and flow, as
there may be not enough flow thorugh
the sea water condenser.
the suction pressure reading is below
the safety levels. Please check the value
of the pressures and try to reset
manually the alarm.
If it does not stop, contact the closest
Climma service center.
There is a proble with one or more
probles. Please check the probes
connections. Try to reset manually the
alarm, then if it does not go away, shut
off the system, wait 1 minute, then try
to restart the system. If the error does
not go eway, contact the closest
Climma service center.
Superheat value is below the threshold
allowed, check and monitor the system.
Try to reset manually the alarm, then if
it does not go away, shut off the
system, wait 1 minute, then try to
restart the system. If the error does not
go eway, contact the closest Climma
service center.
The evaporating temperature of the
system is low, maybe there is not
enough refrigerant or the probe is
faulty. Try to reset manually the alarm,
then if it does not go away, shut off the
system, wait 1 minute, then try to
Installation Manual –Page 15 / 20