High Viscosity Index/Low Pour Point Anti-wear Hydraulic
Fluid, ISO VG 46
Material Properties:
Viscosity, ASTM D445
Viscosity Index ASTM D2270
Pour Point, ASTM D97
Industry Specifications:
Vickers I-286-S (Quality Level), Vickers M-2950-S
(Quality Level), Denison HF-0
Important:
The ISO VG 46 Multigrade fluid has
been found to offer optimal performance in a wide
range of temperature conditions. For operation
in consistently high ambient temperatures, 18° C
(65° F) to 49° C (120° F), ISO VG 68 hydraulic fluid
may offer improved performance.
Premium Biodegradable Hydraulic Fluid-Mobil
EAL EnviroSyn 46H
Important:
Mobil EAL EnviroSyn 46H is the only
synthetic biodegradable fluid approved by Toro.
This fluid is compatible with the elastomers used
in Toro hydraulic systems and is suitable for a
wide-range of temperature conditions. This fluid is
compatible with conventional mineral oils, but for
maximum biodegradability and performance the
hydraulic system should be thoroughly flushed of
conventional fluid. The oil is available in 19 L (5
gallon) containers or 55 gallon drums from your
Mobil Distributor.
Important:
Many hydraulic fluids are almost
colorless, making it difficult to spot leaks. A
red dye additive for the hydraulic system oil is
available in 20 ml (2/3 oz) bottles. One bottle is
sufficient for 15-22 L (4-6 gallons) of hydraulic oil.
Order part no. 44-2500 from your authorized Toro
distributor. This red dye is not recommended for
use with biodegradable fluids.
Important:
Regardless of hydraulic fluid type
used, any machine used for mowing fairways,
verticutting or used during ambient temperatures
above 29° C (85° F) should have Oil Cooler Kit,
Part No. 117-9314, installed.
cSt @ 40°C 44 to 50
cSt @ 100°C 7.9 to 8.5
140 to 160
-34°F to -49°F
Filling the Hydraulic Tank
1.
Position the machine on a level surface.
Note:
Make sure the machine has cooled down
so the oil is cold.
2.
Remove the cap from the reservoir
1. Hydraulic reservoir cap
3.
Slowly fill the reservoir with the appropriate
hydraulic fluid until the level reaches the Full
mark in the white window in the front of the
reservior. Do not overfill.
Important:
contamination, clean the top of the
hydraulic fluid containers before puncturing.
Ensure the pour spout and funnel are clean.
4.
Install the reservoir cap and wipe up any fluid
that may have spilled.
Important:
Check level of hydraulic fluid
before engine is first started and daily
thereafter.
Draining Water from the
Fuel Filter
Service Interval: Before each use or daily
1.
Position the machine on a level surface and stop
the engine.
2.
Place a drain pan under the fuel filter.
3.
Open the drain plug on the fuel filter
approximately one turn and drain any
accumulated water
26