Freeze Resistant Wall Mount Stone Fountains
Installer
To assure you install this model easily and correctly,
PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE
INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH
PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave
these instructions inside the fountain for future reference.
This Freeze Resistant Fountain is shipped in two separate cartons. The second carton
contains the Freeze Resistant Package that is installed on an interior heated wall. Refer to
the Freeze Resistant Package for the rough-in dimensions for installation.
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS,
ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE
BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE
ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH
CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER.
THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY
DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO
ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
3/8" O.D. UNPLATED
1/4" O.D. TUBE
COPPER TUBE CONNECT
WATER INLET
COLD WATER SUPPLY
TO COOLER
NOTE: WATER FLOW
DIRECTION
4592FR_FTN
4593FR _FTN
Owners Manual
IMPORTANT
BUILDING WATER INLET
SERVICE STOP
(NOT FURNISHED)
FIG. 1
PAGE 1
LK4593FR_FTN
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE IS
TUBE TO ATTACH
SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
FIG. 2
97085C (Rev. SIE- 1/11)

Advertisement

loading

Summary of Contents for Halsey Taylor 4592FR

  • Page 1 4592FR_FTN 4593FR _FTN LK4593FR_FTN Owners Manual Freeze Resistant Wall Mount Stone Fountains Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these instructions inside the fountain for future reference.
  • Page 2 4592FR_FTN 4593FR _FTN LK4593FR_FTN 4592FR ROUGH-IN 4593FR ROUGH-IN 97085C (Rev. SIE - 1/11) PAGE 2...
  • Page 3 4592FR_FTN 4593FR _FTN LK4593FR_FTN INSTALLATION INSTRUCTIONS 1. This fountain is to be mounted on a smooth, flat, finished wall surface with adequate support structure. NOTE: Wall mounting structure must be capable of supporting 300 lb. load on fountain. 2. Wall should already be framed for the fountain using dimensions shown in rough-in's on Page 2.
  • Page 4 4592FR_FTN 4593FR _FTN LK4593FR_FTN ITEMIZED PARTS LIST ITEM PART NO. DESCRIPTION 100147140560 Drain Gasket 6 - A 100322740560 Bubbler Gasket 6 - B 101570540560 Drain Gasket 15013C Bubbler Tube Assy. 170705042830 Basin 400942308640 Bubbler 98287C Bubbler Assembly 56092C Poly Tubing (Cut To Length) 56121C Drain Elbow 600985551640...

This manual is also suitable for:

Lk4593fr4593fr