Page 1
Operating and Service Manual 40S6G18-L Model 10046093 Part Number Serial Number 160 School House Road, Souderton, PA 18964 • 215-723-8181 • Fax 866-859-0582 • www.arworld.us...
Page 3
OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 18 December 2006 concerning the Registration, Evaluation, Authorization and Restriction of Substances of Very High Concern Chemicals (SVHC) Supporting documentation is held by AR RF/Microwave Instrumentation’s Quality department in Pennsylvania, United States. Place of issue:...
Page 5
Instructions for European EMC Conformity WARNING It is the responsibility of the user of this equipment to provide electromagnetic shielding, filtering and isolation which is necessary for EMC compliance to Directive 2014/30/EU. The equipment must therefore be operated in a shielded area which provides a sufficient level of attenuation to meet the radiated emissions and immunity specifications.
Page 7
The caution symbol denotes a potential hazard. Attention must be given to the statement to prevent Your AR equipment may have more than one power supply cable. Use damage, destruction, or harm. only approved power cable(s). If you have not been provided with a Dangerous voltages are present.
Page 8
EQUIPMENT CONTAINING LASERS risk of serious injury due to unsafe AR Field Probes (FL/PL Series) and Field Analyzers (FA product handling should be a fundamental Series) are Class 1 laser products containing embedded consideration every user.
Page 9
Zur Vermeidung von Personen- oder Sachschäden gilt BEVOR SIE DAS GERÄT ANSCHLIESSEN es, die Hinweise zu beachten. Ihre AR-Ausrüstung hat möglicherweise mehr als ein Stromversorgungskabel. Gefährliche elektrische Spannungen sind vorhanden. Verwenden Sie nur zugelassene Stromkabel. Falls Sie kein Stromkabel oder Höchste Vorsicht ist geboten.
Page 10
Die meisten Geräte müssen während des Versands, der Montage und des Gebrauchs LASER-INFORMATION transportiert werden. Jeder Nutzer sollte sich AR - Feldsonden (FL/PL-Serie) und Feldanalysatoren (FA-Serie) über das Risiko von schweren Verletzungen sind Laserprodukte der Klasse 1 mit eingebetteten Klasse-4- durch unsachgemäße...
Page 11
électrode de mise à la Votre équipement AR peut disposer de plus d’un câble d’alimentation terre de protection. électrique. Utilisez uniquement un ou des câbles d’alimentation approuves.
Page 12
éliminer le risque injustifié de blessures causées par le levage est fournie par les méthodes de travail de NIOSH (publication Les sondes de champ AR (série FL/PL) et les analyseurs de n° 94-110) disponibles sur : champ (série FA) sont des produits laser de classe 1 contenant des lasers intégrés de classe 4.
Page 13
Er zijn gevaarlijke elektrische spanningen aanwezig. Wees uiterst voorzichtig. VOOR HET OPZETTEN VAN DE STROOM Uw AR-apparatuur kan meer dan een netvoedingskabel bezitten. Gebruik alleen goedgekeurde netvoedingskabel(s). Koopt een Wijst op een terminal aan die bedoeld is voor aansluiting netvoedingskabel die is goedgekeurd voor gebruik in uw land als u...
Page 14
APPARAAT DAT LASERS BEVAT distributie, de assemblage en het gebruik moeten worden behandeld, moet het risico AR-terreinsondes (FL/PL-serie) en terreinanalysatoren (FA- op ernstig letsel als gevolg van een serie) zijn laserproducten van klasse 1 met ingesloten onveilige behandeling van het product een klasse 4-lasers.
TABLE OF CONTENTS TABLE OF CONTENTS ....................v GENERAL INFORMATION ................1 General Description ....................1 Power Supplies ....................... 1 Specifications ......................1 OPERATING INSTRUCTIONS ................ 5 General ........................5 Amplifier Front and Rear Panels ................6 Local Operation ...................... 6 2.3.1 Power-up Sequence ....................
Page 16
4.3.8 Low or No Power Output (DC Tests) (Schematic Diagram # 10045874) ... 27 FIGURES Model 40S6G18-L Front Panel ................6 Model 40S6G18-L Rear Panel ................6 Typical Gain Response @ 0dBm Input ..............26 Typical Gain Response @ -5dBm Input .............. 27 Typical Gain Response @ -20 dBm Input ............
USB, or Ethernet interface. POWER SUPPLIES The Model 40S6G18-L contains a switching power supply. The input voltage range to the power supply is 90–264 VAC, 47-440Hz, selected automatically. PS1 is a multiple output supply. The main +27, +12, -12, +10 and -5 volts DC supplies voltage to the RF low level and final stages.
Page 19
40 Watts CW linearity are required. The Model 40S6G18-L, The Model 40S6G18-L is designed to have low 6GHz–18GHz when used with a sweep generator, will pro- spurious signals, linearity and is extremely load...
Page 20
HARMONIC DISTORTION: Minus 20 dBc maximum at 40 watts EXPORT CLASSIFICATION: 3A001 THIRD ORDER INTERCEPT POINT: 52 dBm typical To order AR Products, call 215.723.8181. For an applications engineer call:800.933.8181. Direct to Service call: 215.723.0275 or email: service@arworld.us For Faxing Orders:866.859.0582 (Orders Only Please) info@arworld.us...
2. OPERATING INSTRUCTIONS GENERAL Operation of the Model 40S6G18-L broadband amplifier is simple. The input signal, whether swept or fixed in frequency, is fed into the jack marked INPUT and the amplifier output signal is taken from the jack labeled OUTPUT.
Model 40S6G18-L AMPLIFIER FRONT AND REAR PANELS Figure 2-1 shows the front panel of the Model 40S6G18-L Broadband Microwave Amplifier. Figure 2-2 shows the rear panel of the Model 40S6G18-L Broadband Microwave Amplifier. Figure 2-1. Model 40S6G18-L Front Panel Figure 2-2. Model 40S6G18-L Rear Panel LOCAL OPERATION 2.3.1...
Model 40S6G18-L REMOTE COMMUNICATIONS This section describes remote operation of this product using the installed communications ports connected to a remote device such as a personal computer. All ports are active at all times, however only one port may be used at a time.
Model 40S6G18-L The RS-232 port is setup as a Data Circuit-terminating Equipment (DCE) port. When connecting to a Personal Computer (PC) a straight one-to-one cable should be used. A null modem is NOT needed. The settings and pinout diagram for this port can be found below.
This port can be used in conjunction with either an AR model IF7000 RS-232 to Fiber-Optic Interface (1200 to 9600 baud only) or an AR model IF7001 USB to Fiber-Optic Interface (19200 baud only). Note that these devices use SMA connectors so a fiber-optic cable is needed with ST connectors on one end and SMA connectors on the other.
Lantronix Ethernet devices. This list of found devices will include any connected AR Ethernet devices. By selecting one of the connected devices from the list, its IP address and subnet mask can be changed along with a number of other settings.
Model 40S6G18-L 2.4.6.1 Power On/Off This command controls the power on/off state of the amplifier. Syntax: POWER:x State(x): Parameters: OFF = power off ON = power on Response Format: None (No query for this command) Example: To turn the power on, send the following command: POWER:ON<LF>...
Model 40S6G18-L 2.4.6.4 Level Adjust This command sets the RF gain of the amplifier. Syntax: LEVEL:xy Parameters: Parameter(x): GAIN = RF Gain Value(y): For RF Gain: 0 = Minimum 100 = Maximum Response Format: None (No query for this command)
Model 40S6G18-L 2.4.6.6 IO Board Firmware Revision Query to get the firmware revision of the I/O Board. Syntax: *IOB? Parameters: None Query only (always requires a ? character) Response Format: INTERFACE_BOARD_SW_REVx<LF> Where: x = firmware revision Example: To get the firmware rev. of the I/O Board, send the following command: *IOB?<LF>...
Model 40S6G18-L NOTE: Bits labeled NOT USED may be read as a bit state of 1 or 0 Table 2-5. States BIT STATE BIT DESCRIPTION NOTES: POSITION (NOT USED) (NOT USED) (NOT USED) Response to Toggle Switch REMOTE CONTROL DISABLED...
Model 40S6G18-L 2.4.6.9 Faults Query to find the faults that have occurred with the amplifier. Syntax: FSTA? Parameters: None Response Format: FSTA=<space>00xx Where: xx = 00 to 1B (Hexadecimal) Decimal Description Interlock Thermal A5 Thermal A4 Thermal A1 PS2 Thermal...
Model 40S6G18-L 2.4.6.11 Operating Hours (Power On) Query to get the Power On operating hours. Syntax: OHP? Parameters: None Response Format: OHP=x<LF> Where: x = 0 to 100000 Units are Hours. Values can be up to six digits in length. Leading zeros are read as spaces.
Model 40S6G18-L 2.4.6.13 System Serial Number Query to get the serial number of the system. Syntax: Parameters: None Query only (always requires a ? character) Response Format: x<LF> Where: x = serial number (6 to 8 characters) Example: To get the serial number, send the following command: SN?<LF>...
Page 34
Model 40S6G18-L Example 1: To set the default RF Gain to 75%, send the following command: DEFAULT:LEVEL:GAIN75<LF> Example 2: To query the default RF Gain setting, send the following command: DEFAULT:LEVEL:GAIN?<LF> Response: DEFAULT:LEVEL:GAIN75<LF> Example 3: To set the default mode to manual, send the following command: DEFAULT:MODE:MANUAL<LF>...
3. THEORY OF OPERATION INTRODUCTION The Model 40S6G18-L RF amplifier consists of a 6.0–18 GHz RF amplifier assembly. The RF amplifier assembly consists of a Pre-Amplifier (Pre-Amp), a Driver Amplifier (Driver Amp), 2 way splitter, two 20- watt output modules and a 2-way combiner.
18 dB or greater and delivers approximately 20 watts of RF power. POWER SUPPLY There are two power supplies in the 40S6G18-L amplifier. Power supply PS1 is a switching supply that automatically sets the AC input circuits to the correct connections for the line voltage 90-132 and 180-250 VAC input ranges 50/60 Hz.
Model 40S6G18-L COOLING SYSTEM Information on the coolant used in the 40S6G18-L: www.koolance.com Manufacturer: Koolance ( Manufacturer Part No: LIQ-702 Safety Data Sheet, reference: Koolance SDS-LIQ-702 Coolant Fluid Maximum pressure that the fluid is under is 15.6 Psi. The amount of fluid is ~300ml (the volume of the reservoir).
4. MAINTENANCE GENERAL MAINTENANCE INFORMATION The Model 40S6G18-L requires very little maintenance since it is a relatively simple instrument. It is built with thin film substrate etched circuit wiring and solid state devices that will ensure long, trouble free life.
GaN and GaAs FETs and other ESD-sensitive devices. Troubleshooting the Model 40S6G18-L in a logical manner can speed the solution to a problem. The settings of potentiometers (pots), capacitors (caps), or other variables should not be disturbed until other problems have been eliminated.
POWER Switch is Depressed (Schematic Diagram No. 10040925) 1. If the Model 40S6G18-L is operating in an otherwise normal fashion, the front panel LCD display or the wiring to it could be defective. 2. Check the LOCAL/REMOTE switch on the unit’s front panel; it must be set to the LOCAL position in order to operate the front panel POWER switch.
RF energy when these doors are opened. NOTE: The Model 40S6G18-L is shipped with a mating connector, which has a jumper between Pins 1 and 8, installed in the rear panel interlock connector. The unit will not operate unless the interlock circuit is closed.
Low or No Power Output (DC Tests) (Schematic Diagram # 10045874) All indicators on the Model 40S6G18-L are normal, the front panel vacuum fluorescent display (VFD) reads Power On, and the cooling fans (B1) is operating. 1. Check the position of the RF Gain control—is it set to maximum gain? 2.
Pin 6, 7 ±0.5V 8. The Model 40S6G18-L’s typical gain response at 0dBm input and –20dBm input is shown in Figures 4-1, 4-2 and 4-3. The actual gain may vary considerably from that shown in Figure 4-1, but should be > 43.5 dB.
Model 40S6G18-L Typical Gain Response @ -5dBm Input Freq, GHz Figure 4-2. Typical Gain at -5dBm Input Typical Gain Response @ -20dBm Input Freq, GHz Figure 4-3 Typical Gain Response @ -20 dBm Input Rev E...
Page 46
Model 40S6G18-L 9. Remove the coaxial cable between the output of the A1A2 Driver Amp, the input of the A3 2-way splitter. The typical response from the input of the A3 2-way splitter to the RF output connector on the unit’s front panel is shown in Figure 4-4.
Page 47
Model 40S6G18-L 11. If the A4 & A5 20-watt module to the RF output connector is normal, check the response of the A1A2 Driver Amp. The gain should be approximately 16-18 dB. See Figure 4-6 for a typical A1A2 Driver Amp response (including the shaper).
Page 49
These modules are not field-repairable and should never be opened outside of AR’s Microelectronics Lab. The modules in these product lines have a security label on two sides of the modules between the housing and lid/cover. If the security label is removed and or cut, the warranty of the module will be voided.