Setup Via Hlp 4200Wd Display; Step-By-Step Setup Instructions - Harmonic PWRLink II 4100S Series Product Manual

Optical transmitter
Table of Contents

Advertisement

4.4

Setup via HLP 4200WD Display

This section provides instructions for setting up the PWL 4100S via the push
buttons and LCD display of the HLP 4200WD equipment platform. To quickly
and easily set up and review the PWL 4100S monitoring and control
parameters, use the HLP 4200WD front panel. For a detailed description of
this interface, see Section 3.1 HLP 4200WD Display on page 3-2.
4.4.1

Step-by-Step Setup Instructions

1. Verify that the PWL 4100S module is properly installed in the HLP 4200
platform. Instructions are provided in Section 2.2 Installing the Transmitter
Module on page 2-1.
2. Verify that the HLP 4200WD is powered on and that no alarm conditions
exist within the transmitter module; make sure that the Status LED on the
front panel is green.
3. Verify that the RF input level per analog carrier is within the range of 15 to
22 dBmV/channel based on 80 NTSC channels.
4. Verify that the RF input signal has been properly connected to the
transmitter. See Section 2.4 Connecting the RF Broadband Input on page 2-4.
5. On the HLP 4200WD, press the
SELECTION
6. Press the
you wish to set up, then press
7. Press
Enter.
CHOOSE
8. Hold down the
displayed—
Enter.
NO
9. The message appears,
Hold down the
displayed—
The transmitter's microprocessor adjusts the RF pad level.
10. The message appears,
Hold down the
displayed—
see Section 4.3.2 Automatic Gain Control and Manual Gain Control.
11. To exit the Transmitter Setup menu, press
PWRLink™ II 4100S Series Optical Transmitter Product Manual Rev A (3/06)
, then press
Enter.
or
button until the display indicates the transmitter module
or
until the display reads
The message appears,
.
button and press
Set
to run Autosetup or
YES
For details of the Autosetup feature, see Section 4.3.1. If you choose
to Autosetup, skip to Step 10.
VIDEO MODULATION <SET+UP/DN> FOR CW.
button and press
Set
CW MODULATION
AGC CONTROL <SET+UP/DN> FOR AGC.
button and press
Set
or
— then press
AGC
MGC
Setup via HLP 4200WD Display
button until the display reads
Esc
Enter.
TRANSMITTER SETUP
RUN AUTOSETUP? YES <SET+UP/DN> TO
or
until the value you want is
to skip Autosetup—then press
NO
or
until the value you want is
or
VIDEO MODULATION
or
until the value you want is
For details of the AGC feature,
Enter.
.
Enter
MODULE
, then press
hen press
t
Enter.
4–7

Hide quick links:

Advertisement

Table of Contents
loading