  • Page 1 SUPRALink™ 7110-Exx Optical Transmitter Installation Guide Rev A Manual Part No. 700-0052027...
  • Page 2 Harmonic assumes no responsibility or liability arising from the use of the products described herein, except as expressly agreed to in writing by Harmonic. The use and purchase of this product do not convey a license under any patent rights, copyrights, trademark rights, or any intellectual property rights of Harmonic.
  • Page 3 用手册的规定,对该产品进行使用或存储。 The Environmental Protective Use Period for Harmonic products is 20 years unless displayed otherwise on the product. The EPUP period is valid only when the products are operated or stored as per the conditions specified in the product manual.
  • Page 4 Safety: UL 60950-1, CSA 60950-1, 21 CFR 1040 (CDRH) Europe Standards EMI/EMC: EN55022, EN55024, EN 6100-3-2, EN6100-3-3 Safety: EN 60950-1, EN 60825-1 Japan Standards EMI: VCCI V-3 / 2007.04 Australia and New Zealand Standards EMI: AS/NZS- CISPR 22:2205 © 2009 Harmonic Inc. All rights reserved.
  • Page 5 CAUTION: The Caution symbol calls your attention to information that, if ignored, can adversely affect the performance of your Harmonic product, or that can make a procedure needlessly difficult. LASER DANGER: The Laser symbol and the Danger alert call your attention to information about the lasers in this product that, if ignored, can cause physical harm to you.
  • Page 6: Table Of Contents

    Table of Contents Chapter 1 Overview About This Manual ......... 8 Description.
  • Page 7 Disclaimer ..........30 Contacting Harmonic Support ....... 31 Appendix A Technical Specifications Optical Output .
  • Page 8: Chapter 1 Overview

    Description The SPL 71 10-Exx transmitter is a compact plug-in module designed for use in the Harmonic HLP 4200 and 4800 equipment platform. An HMC 4001 module carrier is needed to mount the transmitter in the platform. Harmonic has optimized the SUPRALink family of transmitter modules for high-performance transmission of RF broadband information over optical fiber networks.
  • Page 9 Transmitter performance is optimized by combining state-of-the-art 1 550 DWDM distributed feedback (DFB) laser technology and patent pending, pre-distortion linearization circuitry. Harmonic has designed the SUPRALink family for integration into networks with advanced element management systems; each transmitter module employs a microprocessor-based communication and monitoring architecture.
  • Page 10: Applications

    Applications Figure 1-2: SPL 7110-Exx block diagram The SPL 71 10-Exx transmitter is a compact plug-in module that mounts easily in Harmonic’s HLP 4200 and HLP 4800 platform via the HMC 4001 module carrier. For additional information on the HLP 4200 platform and HLP 4800 platform and its associated communication and power buses, see the HLP 4200 Instruction Manual or the HLP 4800 Users’s Guide.
  • Page 11 (not shown) from the forward path signal. In Figure 1-4, the return signal is carried on the same fiber as the forward path signal. Figure 1-4: Application Example 2 © 2009 Harmonic Inc. SPL 7110-Exx, Version 1.0, Rev A...
  • Page 12 In multiwavelength applications, the launch power into the fiber and the total fiber distance may need to be limited and the analog content on each wavelength must be identical to avoid detrimental non-linear fiber optic effects. Consult your Harmonic applications engineer for more details.
  • Page 13: Chapter 2 Installing The Spl 7110-Exx Transmitter

    Receiving and Inspecting As you unpack your unit, inspect the shipping container and equipment for damage. Save the shipping material for future use. If the container or the equipment is damaged, notify both the freight carrier and Harmonic. (see Contacting Harmonic Support on page 31 for contact information).
  • Page 14 For additional information on the HLP 4200 platform and HLP 4800 platform and its associated communication and power buses, see the HLP 4200 Instruction Manual or the HLP 4800 User’s Guide. © 2009 Harmonic Inc. SPL 7110-Exx, Version 1.0, Rev A...
  • Page 15: Connecting The Fiber Cable

    2. Determine the connector type on the SPL 71 10-Exx. The standard optical connector recommended by Harmonic is SC/APC. Other connector types can be special ordered. 3. Verify that the type of connector on the fiber cable is the same as what is on the SPL 71 10-Exx, for example, SC/APC.
  • Page 16: Testing Rf Signal Input

    F-type) located on the front panel of the transmitter module, as shown in Figure 1-1 page 9. The monitor level is 20 dB below the input level to the transmitter ±1.0 dB. © 2009 Harmonic Inc. SPL 7110-Exx, Version 1.0, Rev A...
  • Page 17: Chapter 3 User Interface Options

    SPL 71 10-Exx performance. The Autosetup and Reset to Factory Settings commands are available only through this interface. For initial setup of the transmitter, Harmonic recommends using the HLP 4200 or HLP 4800 display, if available. NETWatch Site Controller Element Management System Once installed and configured, NETWatch Site Controller provides a straightforward way to monitor and control a network of multiple SPL 71 10-Exxs, either locally or remotely.
  • Page 18 For additional information on the HLP 4200 platform and HLP 4800 platform and its associated communication and power buses, see the HLP 4200 Instruction Manual or the HLP 4800 User’s Guide. © 2009 Harmonic Inc. SPL 7110-Exx, Version 1.0, Rev A...
  • Page 19: Transmitter Status

    Figure 3-1: HLP 4200 and HLP 4800 platform Transmitter menu display chart 3.1.1 Transmitter Status The Transmitter Status menu lets you obtain the transmitter serial number, firmware version, and basic operating mode parameters. © 2009 Harmonic Inc. SPL 7110-Exx, Version 1.0, Rev A...
  • Page 20: Transmitter Setup

    Transmitter Alarms menu. NETWatch Site Controller Harmonic’s NETWatch Site Controller provides a complete element management system, including a Windows™-based GUI and communications package for monitoring and controlling a network of multiple SPL 71 10-Exx transmitters either remotely or locally. For information on installing and using this system, consult the NETWatch Site Controller Instruction Manual.
  • Page 21: Chapter 4 Transmitter Setup

    How to set up via NETWatch Site Controller NOTE: For initial setup of the transmitter, Harmonic recommends using the HLP 4200 and HLP 4800 platform’s push buttons and display, if available. If you are using another platform (such as 4200ND) that does not have a display, the NETWatch Site Controller can be used for transmitter setup.
  • Page 22: Returning To Factory Settings

    Factory-Optimized Settings BER (bit error rate) performance Once the Harmonic factory optimizes a SPL 71 10- Exx transmitter, the factory settings are written into the transmitter’s memory. These settings allow the transmitter to achieve the optimal performance at factory setup for any model in the SPL 71 10- Exx series of transmitters.
  • Page 23: Fine-Tuning Each Transmitter

    The Autosetup feature enables you to quickly set the internal drive level to the laser as close as possible to the optimal value determined at the Harmonic factory. The transmitter operates in either the Automatic Gain Control (AGC) mode or the Manual Gain Control (MGC) mode.
  • Page 24: Automatic Gain Control And Manual Gain Control

    AGC, the input level to the transmitter laser remains at its previously established value. When you use AGC mode with the SPL 71 10- Exx, Harmonic recommends that you drive the transmitters 3 dB harder so that they can better compensate for the increased variation in the RF input signal.
  • Page 25: Setting Fiber Length

    Fine-Tuning the Transmitter The setup instructions described in Section 4.4.1. will normally bring the transmitter to optimal operating conditions. Harmonic recommends fine-tuning each transmitter to your specific requirements and preferences. If the factory-optimized RF level is not suitable for your particular application, you can use the following procedure to adjust the internal RF pad.
  • Page 26: Resetting The Transmitter To Factory Defaults

    5. Set the chirp compensation level by changing the fiber length setting to the value closest to the total fiber length traversed by the light from this transmitter. 6. If further adjustment is needed, change the input pad level via the NETWatch Site Controller. © 2009 Harmonic Inc. SPL 7110- Exx, Version 1.0, Rev A...
  • Page 27: Using The Spl 7110- Exx In A Multiwavelength Application

    Consult your Harmonic applications engineer for more details. © 2009 Harmonic Inc.
  • Page 28: Chapter 5 Maintenance

    5.1.1 Cleaning Patch Cord or Pigtail Fiber Optical Connectors To clean optical connectors, Harmonic recommends using a fiber optic connector cleaning cartridge (such as NTT Cletop). If a cleaning cartridge is not available, follow these steps. 1. Fold a piece of unused dry lens cleaning paper twice, for a four-ply thickness.
  • Page 29: Fan Replacement

    SUPRALink 7110-Exx module. Under normal headend and central office environmental conditions, the transmitter can operate without fan cooling for a limited time. Should a fan failure occur, contact Harmonic’s technical service (see 6.2 In Case of Problems on page 30).
  • Page 30: Chapter 6 Troubleshooting

    Return Material Authorization (RMA) Number. You must include this RMA number on the shipping container when returning the unit, and with all correspondence regarding the unit. To return the unit, send it to one of the Harmonic Headquarters addresses listed in D, Harmonic Inc. – Offices. Please add the note: Attn.: Customer Service...
  • Page 31: Contacting Harmonic Support

    Contacting Harmonic Support Contacting Harmonic Support The Harmonic Customer and Technical Support groups are available to help you with any questions or problems you may have regarding Harmonic products. For assistance from within the U.S. and Canada, call toll free: 1.800.730.4099...
  • Page 32: Optical Output

    Return loss: >16 dB Connector type: Female F Level: -20 ±1.0 dB below input Rear panel RF input connector type: Female F Optical output (for connector types available, see Section A.8.) © 2009 Harmonic Inc. SPL 7110S-Exx, Version 1.0, Rev A...
  • Page 33: Power Requirements

    = Connector Type: AS, AF, or AE AS = SC/APC AF = FC/APC AE = E2000 SC/APC is the connector type recommended by Harmonic. Other connector types available upon request. © 2009 Harmonic Inc. SPL 7110S-Exx, Version 1.0, Rev A...
  • Page 34: Laser Radiation Warning

    Always assume that exposed optical connectors and cables are energized. Always make an optical power measurement of the fiber or connector before cleaning or before visual inspection, to ensure that the fiber is not energized © 2009 Harmonic Inc. SPL 7110S-Exx, Version 1.0, Rev A...
  • Page 35: Compliance With Weee

    Harmonic will ensure that all products that cannot be re-used will be recycled in compliance with the WEEE Directive. To that end, users are advised that (1) Harmonic equipment is not to be discarded in household or office garbage, (2) customers may consult the Harmonic web site (www.harmonicinc.com) for additional and updated...
  • Page 36: Appendix B Hlp 4200 And Hlp4800 Menu Display

    Use the HLP 4200 and HLP4800’s buttons to scroll through the menus. Use the Enter button to make a selection. Use the Esc button to escape any menu. © 2009 Harmonic Inc. SPL 7110S-Exx, Version 1.0, Rev A...
  • Page 37 B HLP 4200 and HLP4800 Menu Display Figure B-1: HLP 4200 and 4800WD platform Transmitter menu display, levels 0 and 1 © 2009 Harmonic Inc. SPL 7110S-Exx, Version 1.0, Rev A...
  • Page 38 Harmonic Inc. 549 Baltic Way Sunnyvale, CA 94089, U.S.A. T +1 408 542 2500 F +1 408 490 6708 www.harmonicinc.com © Copyright 2009 Harmonic Inc. All rights reserved. Manual Part No. 700-0052027...