3.1.1
Transmitter Status
The Transmitter Status menu lets you obtain the transmitter serial number,
firmware version, and basic operating mode parameters.
3.1.2
Transmitter Diagnostics
The Transmitter Diagnostics menu allows you to:
• Determine the laser power
• Determine the heat sink temperature
3.1.3
Transmitter Setup
The Transmitter Setup menu allows you to:
• Run the Autosetup routine
• Select Manual Gain Control (MGC) or Automatic Gain Control (AGC)
mode of operation
• Configure the transmitter in either CW or Video mode
3.1.4
Transmitter Adjustments
The Transmitter Adjustments menu allows you to:
• Adjust and optimize the RF pad settings
• Restore all transmitter parameters to the original factory settings
3.1.5
Transmitter Alarms
The Transmitter Alarms menu displays the active alarms in the transmitter.
NOTE: If an alarm condition is triggered in a specific transmitter module,
PWRLink™ II 4100S Series Optical Transmitter Product Manual Rev A (3/06)
when that transmitter is selected through the HLP 4200WD interface,
the display automatically jumps to the alarm message within the
Transmitter Alarms menu.
HLP 4200WD Display
3–5