● Part number legend
C D 2 2
_- _ _ _ _ _ _ _ _ _
Case ● Nul : Aluminum
● M
: SUS316L
Aluminum housing
CD22-15-485□□
Part
number
SUS housing
CD22M-15-485□□
Center of measurement range
Measurement range
Light source
Laser
IEC/JIS
class
※ 1
Spot size
Linearity
Repeatability
※ 2
Sampling period
Temperature drift (typical value)
±0.02% / ℃ of F.S.
Indicator
Communication I/F
Power supply
Current consumption
Protection circuit
Protection category
Operating Temp./Humid.
-10 ~ 50℃ / 35 ~ 85% RH without freasing or condensation
Storage Temp./Humid.
Ambient illuminance
Vibration resistance
Shock resistance
Material
Weight
Aluminum case with M12 connector : Approx. 60g including
SUS case with M12 connector type : Approx. 90g including
ply voltage: 24VDC, Sampling period: 500µs, Averaging: 64, Measuring distance: Center of the range, Testing
object: White ceramic
2
※ 2 512 averaging time
※ 3 Laser Class 2 type (Model: CD22-100-485M122 ,CD22-100-485C2)
Setup
● Changing mode
While it's "Teach mode", "Setup mode" or "Extension mode", you can change the mode 
to "Measurement mode" by pressing "ZERO/RUN" button.
While it's "Setup mode" or "Extension mode", the LED "MANUAL" is lit.
Measurement
mode
Teaching mode
Setup mode
Extension mode
● Changing parameters
You can choose and adjust the parameters by pressing "+" and "-" buttons.
The mode will be changed to "Measurement mode" by pressing "ZERO/RUN" button.
Changing
parameter
Ramco National - Optex FA Sensors
Communication
Laser Class
● Nul : Class 1
● 2
: Class 2
Connector
● M12 : M12
● C
: M8 connector
Output
● V
: Voltage 0-10V
● A
: Current 4-20mA
● -485 : RS-485
Measurement center distance (mm)
CD22-35-485□□
CD22-100-485□□
CD22M-35-485□□
CD22M-100-485□□
15mm
35mm
±5mm
±15mm
Red laser Diode (wave length 655nm)
Max. output: 390 µW
Max. output: 1mW
500 * 700µm
450 * 800µm
0.1% of F.S.
0.1% of F.S.
1µm
6µm
500µs / 1000µs / 2000µs / 4000µs / AUTO
±0.02% / ℃ of F.S.
±0.05% / ℃ of F.S.
Laser indicator: Green / Zero reset indicator: Red
Output indicator: Orange / Mode indicator: Red
RS-485 Half Duplex (Multi-drop I/F is not supported)
12-24VDC ± 10%
70mA max.
Reverse connection protection, Over current protection
IP67 including connection part
-20 ~ 60℃ / 35 ~ 85%/RH
Incandescent lamp: 3,000 lx max.
10 ~ 55Hz, Double amplitude 1.5mm, X,Y,Z for 2 hours
2
500mm/s
( approx. 50G) X,Y,Z 3 times each
Case: Aluminum/SUS316L, Front lens: PPSU, Display: PET
300mm cable with connector
300mm cable with connector
Aluminum case with M8 connector : Approx. 40g
SUS case with M8 connector : Approx. 70g
Press at a time
for 2 second
Adjusting
parameter
SET
www.Optex-Ramco.com
Teach mode
■1:
Setup mode
mEnu
■2:
Teaching mode
modE
■3:
Calibration(Far end of the range)
calf
■4:
Calibration(Near end of range)
100mm
±50mm
CALn
※ 3
■5:
FGS2 threshold
FG52
600 * 700µm
0.1% of F.S.
20µm
■6:
Near side threshold
nEAr
■7:
1 point Teaching - Far side threshold
FAr
Measurement mode
CD22 has 3 measurement mode. The mode is chosen by "Teach mode".
Output can be reversed by setting "Output polarity
Following output shows its ON/OFF status as "Light ON
●1 point Teaching
Teaching is done at a position. When the measurement distance is closer than that position, the output
will be ON.
℃ , Sup-
●2 point Teaching
Teaching is done at 2 positions. While the measurement distance is between those positions, the output
will be ON.
●FGS2
Teaching is done at a position. When the measurement distance is closer than the distance set by "Hys
teresis
toL
●Calibration (Far end of the range/ Near end of range)
The sensor can be calibrated by "Calibration" mode at both far and near end of the measurement range.
This feature is very useful especially when you can't mount the sensor head parallel to the object surface.
Example of Calibration of CD22-100
A)Calibration condition at the factory
Position of the target
-50mm(Near end of the range)
0mm(Reference distance)
50mm(Far end of the range)
Just calibrate the sensor by "Calibration" mode at far end and near end of the measurement range.
Then, you will get calibrated result if the sensor head is tilted.
■ Setting parameter table
Setting
SET
To Setup mode
1pt
1 point Teaching
SET
fG52
FGS2
2pt
2 point Teaching
SET
tch
Teaching current position
SET
tch
Teaching current position
SET
tch
Teaching current position
SET
tch
Teaching current position
SET
tch
Teaching current position
".
 
Acti
L on
FAr
Measurement range
ON
OFF
hYSt
FAr
ON
OFF
hYSt
"from the position that Teaching is done, the output will be ON. It works as FGS sensor.
FGS2
toL
ON
OFF
hYSt
hYSt
B)When the sensor is mounted tilted
measurement result:
-50.00
measurement result:
50.00
Got Questions? 1-800-280-6933
Address/
DATA1
DATA2
Parameter
(upper)
(lower)
switching
".
nEAr
hYSt
Measurement range
measurement result:
SET
-49.81
-50.00
cALn
measurement result:
SET
50.19
50.00
cALF
Description