Internal Components - Metrologic MX001 Installation And User Manual

Industrial control interface
Table of Contents

Advertisement

I
C
NTERNAL
OMPONENTS
The following illustration and list explain the parts that pertain to the installation
and operation of the MX001.
2
3
4
11
5
1. Power Transformer
2. F2 Control Fuse Holder
3. F1 TRIAC Fuse Holder
4. Power Terminal Block
(Line Power Input)
5. TRIAC Terminal Block
(Controlled Power Output)
6. LED Status Indicators
7. Voltage Selector Switch
8. J1 Jumper
9. J2 Jumper
10. Sensor Terminal Block
11. Protective Earthing Connectors
F2
Control
F1
TRIAC
D1
C
12V
Triac
Figure 1
1
7
D2
D3
D4
C
C
C
S IN
A IN
6
Supplies a stepped down and isolated voltage that
produces the 12V DC power for the industrial
control box and external sensor.
Contains the fuse that controls the 12V DC power
in the industrial control box.
Contains the fuse that controls the power for the
TRIAC output.
Provides the input connection point for the AC line
that supplies
power to the industrial control box.
Provides the output connection point
for the scanner controlled.
power output (switched by the TRIAC).
These light up when the +12V power
supply, TRIAC, sensor, or sensor alarm circuits are
active.
Used to configure the industrial control
box to match the incoming line voltage.
Configures sensor input.
Configures the sensor alarm input.
Provides the connection points for the sensor.
To connect line cord protective earthing conductors to
industrial control box enclosure.
9
10
J2
J1
8
3