Sensors That Provide Switch Closures Or Relay Type Output - Metrologic MX001 Installation And User Manual

Industrial control interface
Table of Contents

Advertisement

S
S
ENSOR
UPPORT

Sensors that Provide Switch Closures or Relay Type Output

1.
Make sure power is not being applied to the unit.
2.
Open the terminals in the sensor terminal block by turning each screw
counterclockwise until there is enough space to insert wires.
3.
Strip off 2 ¼ inches of the sensor cable's outer jacket
4.
Strip the insulation off each cable wire ¼ of an inch.
5.
Feed the sensor cable through the small strain relief.
6.
Insert one of the sensors signal output wires into the COMMON terminal
and secure the wire by turning the terminal's screw clockwise. (Refer to the
MX001 box or to Figure 8 for the order of the terminals for the sensor
wires.)
7.
Insert and secure the sensor's other signal output wire into the S IN-
terminal.
8.
Secure the cable by turning the strain relief's domed sealing nut clockwise
until tight.
9.
Position the jumper on pins 5 and 6 of the J1 (S SET UP) header. (Refer to
Figure 9).
Figure 8
1
2
3
1
S SET UP
Figure 9
J1
4
5
6
6
17

Advertisement

Table of Contents
loading

Table of Contents