Connecting The Ac Power Input Cable - Metrologic MX001 Installation And User Manual

Industrial control interface
Table of Contents

Advertisement

C
ONNECTING THE
1.
Make sure power is not being applied to the power cable that is to be
connected to the unit.
2.
Open the terminals in the power terminal block by turning each screw
counterclockwise until there is enough space to insert wires.
3.
Strip off 1 ¾ inches of the power cable's outer jacket.
4.
Strip the insulation off each cable wire ¼ of an inch.
5.
Feed the power cable through the first, large strain relief on the left.
6.
Connect each wire to the appropriate locations noted in the table below and
secure the wires in the terminal block and protective earthing terminal by
turning each screw clockwise. (Refer to the MX001 box or to Figure 4 for the
order of the terminals for the power wires.)
7.
Secure the cable by turning the strain relief's domed sealing nut clockwise
until tight.
Protective
Earthing
Terminals
NOTE: Do not connect any wires to the first terminal.
Terminal Block
Neutral
Line In
Protective
Earthing
Terminals
Ground
10
AC P
I
OWER
NPUT
Figure 4
Cable Color in USA
and Canada
White
Black
Cable Color in USA
and Canada
Green
C
ABLE
Cable Color in
in Europe
Blue
Brown
Cable Color in
in Europe
Yellow-Green