FITTING THE PROGRAMMABLE ROOM THERMOSTAT TRANSMITTER
IMPORTANT: The Receiver and Transmitter are supplied as a 'matched pair' and MUST be installed together. Also, in the case of replacement BOTH items must be renewed.
1. Ensure that there is power to the boiler and that the boiler is turned ON.
2. Remove the rear panel of the Programmable Room Thermostat Transmitter and, noting the polarity, fit the batteries (2 x1.5V L R6/AA) supplied. Press the Reset Button on the
Transmitter - the Transmitter will begin to communicate with the Receiver within 30 seconds. The Receiver will pick up a signal - this can be confirmed by switching on the
Transmitter to create a demand and observing the LED Indicator - see the section ' OPERATING MODE ' below.
3. Secure the rear panel of the Transmitter to a suitable wall in the living room or hall. Refit the Transmitter in place on the rear panel.
OPERATING RANGE: Within a building - up to 20 metres. IMPORTANT: Avoid positioning large metallic objects, including mirrors, in the 'line - of - sight'
between the Transmitter and Receiver as the communication between the two will be adversely affected.
NOTE: Boiler is IP20 when the receiver is fitted - this affects the positioning of the boiler in bath and shower rooms
Programmable Room
Thermostat Transmitter
The Programmable Room Thermostat Transmitter has two temperature operating
levels, 'Hi' and 'Lo'.
'Hi' Mode: This is set using the 'Hi' dial (5°C to 30°C) and will set the temperature to
the level desired when the property is occupied (e.g. 21°C).
'Lo' Mode:This is set using the 'Lo' dial (5°C to 15°C) and will set the temperature to
the level desired when the property is unoccupied or at night (e.g. 10°C).
To Set The Time: Slide the cover (A) off the unit. Rotate the timer clock clockwise
until the time is correct as indicated by the timer pointer.
To Set The 'Hi' & 'Lo' Central Heating Times: Move the tappets outwards for
'Hi' times and inwards for 'Lo' times. Each tappet = 15 minutes.
Summer: During the summer it is recommended that 'Lo' is selected using the 3
position switch.
Holiday Periods: When going on holiday set both dials to 5°C to provide frost
protection of the property.
'Hi' & 'Lo' Room Temperature Dials
A
Lo
Hi
12
9
6
Hi
Lo
12
Rotate to
adjust time
9
'Hi'
range
6
Hi
Lo
Timed
'Hi' Position
between 'Hi'
'Lo'
& 'Lo' ranges
range
Slot for Flat Bladed
Screwdriver
(twist slightly to release)
SETTING THE PROGRAMMABLE ROOM THERMOSTAT
Quick Reference Guide
Hi
i
Operating Modes:
See rear of removable cover
5°C
30°C
To Set Time:
Rotate Outer Ring
To Adjust Temperature:
Rotate Small Dials
Low Battery:
If
flashes yellow the
3
batteries need changing
LOW BATTERY
Reset:
Press
RESET
if in emergency
mode or immediately after
changing batteries
5°C
15°C
RESET
Lo
Reset Button
Operating Mode
label on rear face
Timer Pointer
Switch
Tappet
Position
Position
3
Hi
Lo
Hi
or
Tappet
Hi
Lo
'Lo' Position
Hi
or
Lo
Lo
To Set The Operating Mode: Slide the three position selector switch
to the desired position:-
Hi
= Temperature maintained at 'Hi' setting (irrespective of tappet position)
= Temperature alternates between 'Hi' & 'Lo' temperature periods
= Temperature maintained at 'Lo' setting (irrespective of tappet position)
Lo
Receiver
If the LED is Off then the Central Heating is Off.
If the LED is On then the Central Heating is On.
If the LED is continuously flashing once every 2 seconds then the batteries in the
Programmable Room Thermostat Transmitter are low & will soon require replacement.
If the LED is continuously flashing twice every second then the batteries in the
Programmable Room Thermostat Transmitter must be replaced immediately.
Programmable Room Thermostat Transmitter
If the LED is continuously flashing YELLOW once every 2 seconds then the batteries in
the Programmable Room Thermostat Transmitter are low & will soon require
replacement. If the LED is continuously flashing RED twice every second then the
batteries in the Programmable Room Thermostat Transmitter must be replaced
immediately.
Emergency Mode
If the receiver LED is continuously flashing 2 or 3 times a second then communication
between the Receiver & Transmitter has been lost. In this instance the Receiver enters
Emergency Mode. The Central Heating will operate for 3 minutes, followed by an Off period
of 9 minutes, then 3 minutes On again, repeating this sequence until the fault has been
rectified.
The unit will enter Emergency Mode when the following occurs:-
i) Communication between the Receiver & Transmitter is lost for over an hour.
ii) The batteries have become discharged.
NOTE: When Emergency Mode is activated Baxi Group cannot be held liable for any
Temperature
Set Point
excess consumption of gas.
Hi
5°C
30°C
Re-establishing Communication
5°C
15°C
The communication between the Receiver & Transmitter can be re-established at any time
Lo
by pressing the Reset button on the Transmitter. This must be done every time the batteries
Hi
are renewed.
5°C
30°C
NOTE: When any of the Room Thermostat settings have been changed they will normally
5°C
15°C
be communicated to the receiver unit on the boiler within 20 seconds, but may under certain
Lo
circumstances take up to 3 minutes.
720113801
Receiver
Rear Panel
Batteries
OPERATING MODE
LED Indicator
Hi

Advertisement

loading