Drain Connection; Water Supply - Rational Combi-Steamer CCD Series Manual

Table of Contents

Advertisement

Important installation information – Floor models
Location
incorrect
• Unit must be positioned on level and solid floor area.
• Bear in mind the weight of the Combi-Steamer
CCD 201: 346,5 kg
• The unit must be lined up horizontally in all directions.
• Slope/incline of floor can be compensated by the adjustable feet
(adjusting range: +/- 15 mm).
• The oven rack has to be positioned vertically in the unit.
• Fix the units feet to the floor.
• Minimum Distances:
left 50 mm, right 50 mm is recommended.
• During planning allow enough room
(CCD 201: 730 mm and CCD 202: 810 mm width) for the mobile
oven rack.
• Working area sound emission level:
CCD 201: 49 dB(A)
Exhaust
An extractor hood is not necessary.
In case an extractor hood should be installed:
• The canopy should protrude 300 to 500 mm beyond the front of
the unit.
• Add fat filter to the protruding part of the canopy.
• Heat load
latent:
CCD 201: 7,670 kJ/h
noticeable:
CCD 201: 9,600 kJ/h
• Option:
Connection of hood (for assembly see insert) .
Power connection
Before connecting check details given on the
identification plate, VDE standard requirements, and
requirements of your local electricity board.
CCD 201
Load:
37,2 kW
Fuses:
3 x 63 A
Voltage:
400 V 3N AC
• Special voltages on request, for circuit diagram see inside the unit.
• Electrical connection behind the swing-out service door. Lead type:
e.g. HO7RN-F.
• Location: a main isolator with min. 3 mm phase contact must be
provided.
• Every unit must have its own protected supply conductor.
• The unit is to be integrated into an equipotential bonding system.
The units must be installed by a qualified electrician.
• Use a steam temperature resistant pipe – not a hose pipe.
correct
• A permanent connection with a syphon is possible:
CCD 202: 483,5 kg
• 50 mm standard pipe with constant slope (min. 5% resp. 3°)
• Ensure a sufficient drain size: the pumped discharge rate of the
• Waste water temperature is approx. 65 °C.
• Standard valid:
CCD 202: 49 dB(A)
We recommends to install the following components into the drinking
water supply line (see picture):
• A particle filter (0,08mm) with excessive soiling
• A pressure regulator with 300kPa (3 bar) secondary side setting with
CCD 202: 13,350 kJ/h
• An active carbon filter with a clorine concentration of more than
CCD 202: 15,340 kJ/h
• Connect to cold water, only drinking water quality.
• Safety combination (non-return valve) integrated as standard.
• Connection: 1/2" pressure hose with R 3/4" screwed fitting.
EA
• Customer-fitted water shut-off valve for each appliance.
• Water pressure:
• Observe standards of local water board.
CCD 202
• Optional Treated Water Connection (WZ 2)
63 kW
3 x 100 A
400 V 3N AC
• Electrical:

• Drain connection:

• Water supply:

5 6
Drain connection
min. DN 50
min. 5% / 3°
the unit has an integrated vented-drain.
steam generator is 0,7 ltr./sec.
Water supply
active
3/4"
carbon
filter
of the supply water;
line pressure peaks of above 600kPa (6 bar);
30mgr/liter;
recommended pressure:
(see Installation diagramm) with 2 water supplies:
1. "Normal water" for quenching system and steam
generator flushing system
2. "Treated water" for steam generator, moistening
and hand shower
Theoretical water consumption of the steam generator:
20 x 1/1 GN: 0,83 ltr./min.
20 x 2/1 GN 1,0 ltr./min.
Standards
WA
DIN 1986, P 1
WZ
300kPa
3/4"
particle
filter
150 to 600 kPa
300 kPa
DIN VDE 0700, EN 60335-1
DIN 1986, P 1
DIN 1988, P 4