Control Panel - Rational Combi-Steamer CCD Series Manual

Table of Contents

Advertisement

Control panel

0
60
300
100
250
150
200
D
5
120
10
100
15
80
20
60
40
25
30
99
20
1
Warning indicator lamp – "Lack of water" – check water supply.
Warning indicator lamp
2
• (red flashing) when the interior cabinet temperature during steamin
above 115 °C.
3
ON indicator lamp (green).
4
Mode selecting switch
5
"Steaming" mode (100 °C).
• For steaming, stewing, blanching, preserving ...
• Temperature is set at 100
6
"Hot Air" mode (60 °C – 300 °C).
• For roasting, baking, grilling and gratinating ...
7
"Combi-Steaming" mode (100 °C – 300 °C).
• For Combi-Steaming instead of roasting and glazing or baking with m
• Forced steaming between 101 °C – 130 °C, firm vegetables or potatoe
cooked quicker.
8
Additional function "Cool down"
• Heat-reduction in cooking area, fan wheel rotates when the door is
Control Setting
9
Temperature selecting switch
• For "Hot Air" and "Combi-Steaming" modes.
10
Heating ON indicator
• Lights during heating-up.
11
Timer (0 mins – 120 mins).
• "D" = continuous duty.
Core temperature display (20° C – 99° C) – (option).
12
• Indicates chosen core temperature.
• Indicates actual core temperature.
13
Core temperature pre-selection switch – (option).
20 – 99 °C
Unit serial number
14
Please indicate in case of after-sales servicing!
°C.
5

Hide quick links: